Connection cable

Power supply cord

Terminal Board

Control 
Board

Recommended 

length (mm)

Earth Wire 
longer than 
others 
AC wires 
for safety 
reason

Holder

Holder

Indoor & outdoor 
connection cable

Power supply 

cord

Outdoor unit

Isolating Devices

Tape

Tape

 

How to pull the piping and drain hose out, in case of the 
embedded piping.

 

In case of left piping how to insert the 
connection cable and drain hose.

The mounting wall shall be strong and solid enough to prevent it from vibration.

The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.

Install the indoor unit on the installing holder that mounted on the wall.

Open the front panel and grille door by loosening the screw.

Cable connection to the power supply through Isolating Devices (Disconnecting means).

 

Connect the approved polychloroprene sheathed 

power supply cord

 3 x 1.5 mm

2

 (3/4 ~ 1.75HP) or 3 x 2.5 mm

2

 (2.0HP), type designation 

60245 IEC 57 or heavier cord to the terminal board, and connect the other end of the cable to Isolating Devices (Disconnecting means).

 

Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short.

 

In unavoidable case, joining of power supply cord between isolating devices and terminal board of air conditioner shall be done by using 
approved socket and plug rated 15/16A (3/4 ~ 1.75HP) or 16A (2.0HP). Wiring work to both socket and plug must follow to national wiring 
standard.

Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.

Connection cable

 between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 1.5 mm

2

 (3/4 ~ 1.75HP) or 4 x 

2.5 mm

2

 (2.0HP) fl exible cord, type designation 60245 IEC 57 or heavier cord.

Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right escapement.

Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor unit according to the diagram below.

Terminals on the outdoor unit

S1

2

3

Colour of wires (connection cable)

Terminals on the indoor unit

L

1

N

S1

2

3

(Power supply cord)

Terminals on the isolating devices 
(Disconnecting means)

(L) (N)

Note:

 

Isolating Devices (Disconnecting means) should have minimum 3.0 mm 
contact gap.

 

Ensure the colour of wires of outdoor unit and the terminal Nos. are the 
same to the indoor’s respectively.

 

Earth wire shall be Yellow/Green (Y/G) in colour and longer than other 
AC wires as shown in the fi gure for the electrical safety in case of the 
slipping out of the cord from the anchorage.

Cover for the 
bottom piping

Cover for the 
bottom piping

Tape it with piping in a 
position as mentioned 

in Fig. below.

Cover for 
the right 
piping

Piping

Drain 
hose

Cover for 
the left 
piping

Install the indoor unit

Hook the indoor unit onto the 
upper portion of installation 
plate. (Engage the indoor unit 
with the upper edge of the 
installation plate). Ensure the 
hooks are properly seated 
on the installation plate by 
moving it in left and right.

Secure the Indoor Unit

Press the lower left and right 
side of the unit against the 
installation plate until hooks 
engages with their slot (sound 
click).

Rear view for left piping installation

Drain cap

Drain hose

Adjust the piping slightly 
downwards.

Drain hose

Connection cable

 

PVC tube 
for drain 
hose

Indoor unit

100 mm

Piping

Cable

Apply putty or 
caulking material 
to seal the wall 
opening.

Connection cable

Piping

More than 

470 mm

More than 

950 mm

PVC tube (VP-65) for piping 
and connection cable

PVC tube for drain hose (VP-30)

PVC tube for drain 
hose (VP-20)

More than 700 mm

Drain hose 
from main unit

HOW TO TAKE OUT FRONT GRILLE

Please follow the steps below to take out front grille if necessary 
such as when servicing.
1. 

Set the vertical airfl ow direction louvers to the horizontal 
position.

2. 

Remove the 2 caps on the front grille as shown in the 
illustration at right, and then remove the 3 mounting screws.

3. 

Pull the lower section of the front grille towards you to 
remove the front grille.

When reinstalling the front grille, carry 
out above step 2 - 3 in the reverse order.

AUTO SWITCH OPERATION

The below operations will be performed by pressing the “AUTO” switch.
1. 

AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto Switch is pressed and release before 5 sec..

2. 

TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to 
below 8 sec..
A “pep” sound will occur at the fi fth sec., in order to identify the starting of Test Run operation.

3. 

HEATING TRIAL OPERATION
Press the “AUTO” switch continuously for more than 8 sec. to below 11 sec. and release when a “pep pep” 
sound is occured at eight sec. (However, a “pep” sound is occurred at fi fth sec..) Then press Remote controller 
“A/C Reset” button once.
Remote controller signal will activate operation to force heating mode.

4. 

REMOTE CONTROLLER RECEIVING SOUND ON/OFF
The ON/OFF of Remote controller receiving sound can be change over by the following steps:

a)  Press “AUTO” switch continuously for more than 16 sec. to below 21 sec..

A “pep”, “pep”, “pep”, “pep” sound will occur at the sixteenth sec..

b)  Press the “A/C Reset” button once. Remote controller signal will activate the Remote controller sound setting 

mode.

c)  Press the “AUTO” switch once to select Remote controller receiving sound ON/OFF. A “peep” sound indicates 

receiving sound ON, and a “pep” sound indicates receiving sound OFF.

5. 

HEATING ONLY OPERATION
Press the “AUTO” switch continuously for more than 8 sec. to below 11 sec. And release when a “pep pep” sound 
is occurred at eighth sec. (However, a “pep” sound is occurred at fi fth sec.) Then press Remote controller “Check” 
button once. Remote controller signal will activate heating only operation mode.

DISPOSAL OF OUTDOOR UNIT DRAIN WATER

 

If a drain elbow is used, the unit should be placed on a stand which is taller than 3 cm.

 

If the unit is used in an area where temperature falls below 0°C for 2 or 3 days in 
succession, it is recommended not to use a drain elbow, for the drain water freezes 
and the fan will not rotate.

ECO SENSOR

 

Do not hit or violently press the sensor.
This can lead to damage and malfunction.

 

Do not place large objects near the sensor and keep heating units or humidifi ers away 
from the sensors detection area.
This may lead to sensor malfunction.

 WARNING

This equipment must be 
properly earthed.

Recommended 
length (mm)

a

b

c

d

e

f

g

55 35 35 50 40 35 60

1.  FOR THE RIGHT REAR PIPING

Step-1

Pull out the Indoor piping

Step-2

Install the Indoor Unit

Step-3

Secure the Indoor Unit

Step-4

Insert the power supply cord and 
connection cable

 

Insert the cables from bottom of the 
unit through the control board hole until 
terminal board area.

2.  FOR THE RIGHT AND RIGHT 

BOTTOM PIPING

Step-1

Pull out the Indoor piping

Step-2

Install the Indoor Unit

Step-3

Insert the power supply cord and 
connection cable

 

Insert the cables from bottom of the 
unit through the control board hole until 
terminal board area.

Step-4

Secure the Indoor Unit

3.  FOR THE EMBEDDED PIPING

Step-1

Replace the drain hose

Step-2

Bend the embedded piping

 

Use a spring bender or equivalent to bend 
the piping so that the piping is not crushed.

Step-3

Pull the connection cable into Indoor 
Unit

 

The power supply cord and indoor unit 
and outdoor unit connection cable can be 
connected without removing the front grille.

Step-4

Cut and fl are the embedded piping

 

When determining the dimensions of the 
piping, slide the unit all the way to the left 
on the installation plate.

 

Refer to the section “Cutting and fl aring 
the piping”.

Step-5

Install the Indoor Unit

Step-6

Connect the piping

 

Please refer to “Connecting the piping” 
column in outdoor unit section. (Below 
steps are done after connecting 
the outdoor piping and gas-leakage 
confi rmation.)

Step-7

Insulate and fi nish the piping

 

Please refer to “Insulation of piping 
connection” column as mentioned in 
indoor/outdoor unit installation.

Step-8

Secure the Indoor Unit

Right Rear piping

Cover for 
the bottom 
piping

Tape it with piping in a 
position as mentioned 

in Fig. below.

Cover for 
the right 
piping

Piping

Drain hose

Cover for 
the left 
piping

Right and Right Bottom piping

(This can be used for left rear piping and bottom piping also.)

CHECK ITEMS

Drain hose

Sleeve for piping hole

Indoor unit

Hooks at installation 
plate

Piping

 marking

Installation 
plate

Unit’s hook

Cable

45°

Drain 
hose

Piping

Sleeve for piping hole

Drain hose

Piping

Connection cable

More than 950 mm

 

Do not turn over the unit without it’s shock absorber during pull out the piping.
It may cause intake grille damage.

 

Use shock absorber during pull out the piping to protect the intake grille from damage.

Piping

Intake grille

Shock absorber

Piping

pull ou

t th

e p

ipin

g

pull o

ut t

he

 p

ip

in

g

 

After selecting the best location, start installation to Indoor/Outdoor Unit Installation Diagram.

1. 

Fix the unit on concrete or rigid frame fi rmly and horizontally by bolt nut (ø10 mm).

2. 

When installing at roof, please consider strong wind and earthquake.
Please fasten the installation stand fi rmly with bolt, screws or nails.

INDOOR UNIT

OUTDOOR UNIT

HOW TO FIX INSTALLATION PLATE

2

SELECT THE BEST LOCATION 

(Refer to “Select the best location” section)

1

TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING

3

The center of installation plate should be at more than 

1

 at right and left of the wall.

The distance from installation plate edge to ceiling should more than 

2

.

From installation plate center to unit’s left side is 

3

.

From installation plate center to unit’s right side is 

4

.

b

  :  For left side piping, piping connection for liquid should be about 

5

 from this line.

 

:  For left side piping, piping connection for gas should be about 

6

 from this line.

1. 

Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)

 

Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge.

2. 

Drill the piping plate hole with ø70 mm hole-core drill.

 

Line according to the left and right side of the installation plate.
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.

 

Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.

1. 

Insert the piping sleeve to the hole.

2. 

Fix the bushing to the sleeve.

3. 

Cut the sleeve until it extrudes about 15 mm from the wall.

 

CAUTION

When the wall is hollow, please be sure to use 
the sleeve for tube assembly to prevent dangers 
caused by mice biting the connection cable.

4. 

Finish by sealing the sleeve with putty or caulking 
compound at the fi nal stage.

15 mm

Putty or caulking compound

ø70 mm through hole

Indoor

Outdoor

Sleeve for tube 
assembly

Approx. 5 - 7 mm

Bushing for tube 
assembly

Wall

CONNECT THE CABLE TO THE INDOOR UNIT

5

Cover for piping

How to keep the cover

In case of the cover is cut, keep 
the cover at the rear of chassis as 
shown in the illustration for future 
reinstallation. 
(Left, right and 2 bottom covers for 
piping.)

To take out the unit, push 
the 

 marking at the 

bottom unit, and pull it 
slightly towards you to 
disengage the hooks 
from the unit.

(For the right piping, follow the same procedure)

Is there any gas leakage at fl are nut connections?

Has the heat insulation been carried out at fl are nut 
connection?
Is the connection cable being fi xed to terminal board 
fi rmly?
Is the connection cable being clamped fi rmly?

Is the drainage ok? 
(Refer to “Check the drainage” section)
Is the earth wire connection properly done?

Is the indoor unit properly hooked to the installation 
plate?
Is the power supply voltage complied with rated value?

Is there any abnormal sound?

Is the cooling/heating operation normal?

Is the thermostat operation normal?

Is the remote control’s LCD operation normal?

SELECT THE BEST LOCATION 

(Refer to “Select the best location” section)

1

INSTALL THE OUTDOOR UNIT

EVACUATION OF THE EQUIPMENT

PIPING INSULATION

2

4

6

CONNECT THE CABLE TO THE OUTDOOR UNIT

5

INDOOR UNIT INSTALLATION

4

Model

Dimension

1

2

3

4

5

6

Z7***, XZ7***, Z9***, XZ9***
Z12***, XZ12***, Z15***
Z18***, XZ18***

515 mm

82 mm

460 mm

460 mm

43 mm

95 mm

1. 

Please cut using pipe cutter and then remove the burrs.

2. 

Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. 
Turn the piping end down to avoid the metal powder entering the pipe.

3. 

Please make fl are after inserting the fl are nut onto the copper pipes.

When properly fl ared, the internal surface of the 
fl are will evenly shine and be of even thickness. 
Since the fl are part comes into contact with the 
connections, carefully check the fl are fi nish.

 Improper  fl aring 

Inclined Surface 

damaged

Cracked Uneven 

thickness

CUTTING AND FLARING THE PIPING

1.  To cut

2.  To remove burrs

3.  To fl are

Bar

Red arrow mark

Handle

Core

Yoke

Clamp handle

Bar

0 – 0.5 mm

Copper pipe

Reamer

Point down

Pipe

Guide 
surface

Connection cable

About 

70 – 80 mm

Connection cable

Gas side piping

Liquid side piping

Drain hose

Insert the connection cable

1. 

Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap the 
insulated piping end to prevent water from going inside the piping.

2. 

If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAM with 
thickness 6 mm or above.

WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the 
following procedure.

Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.

There is no extra refrigerant in the outdoor unit for air purging.

1. 

Connect a charging hose with a push pin to the Low side 
of a charging set and the service port of the 3-way valve.

 

Be sure to connect the end of the charging hose with 
the push pin to the service port.

2. 

Connect the center hose of the charging set to a 
vacuum pump.

3. 

Turn on the power switch of the vacuum pump and 
make sure that the needle in the gauge moves from 
0 cmHg (0 MPa) to –76 cmHg (–0.1 MPa). Then 
evacuate the air approximately ten minutes.

4. 

Close the Low side valve of the charging set and turn 
off the vacuum pump. Make sure that the needle in the 
gauge does not move after approximately fi ve minutes.
Note :   BE SURE TO TAKE THIS PROCEDURE IN 

ORDER TO AVOID REFRIGERANT GAS 
LEAKAGE.

5. 

Disconnect the charging hose from the vacuum pump 
and from the service port of the 3-way valve.

6. 

Tighten the service port caps of the 3-way valve at a torque of 18 N•m with a torque wrench.

7. 

Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to “OPEN” using a hexagonal 
wrench (4 mm).

8. 

Mount valve caps onto the 2-way valve and the 3-way valve.

 

Be sure to check whole system for gas leakage.

 

If gauge needle does not move from 0 cmHg (0 MPa) to –76 cmHg (–0.1 MPa), in step 

3

 above take the following measure:

-  If the leak stops when the piping connections are tightened further, continue working from step 

3

.

-  If the leak does not stop when the connections are retightened, repair location of leak.
-  Do not release refrigerant during piping work for installation and reinstallation.
-  Take care of the liquid refrigerant, it may cause frostbite.

OPEN

CLOSE

Gas side

Liquid side

Outdoor unit

Two-way valve

Three-way valve

Indoor unit

Vacuum 
pump

Close

Close

2/2

 WARNING

This equipment must be properly earthed.

 

Earth wire shall be Yellow/Green (Y/G) in 
colour and longer than other AC wires for 
safety reason.

ENGLISH

ACXF60-01930-AB

PRINTED IN MALAYSIA

Model

A

B

C

D

Z7***, XZ7***

570 mm

105 mm

18.5 mm

320 mm

Z9***, XZ9***

Z12***, XZ12***

540 mm

160 mm

18.5 mm

330 mm

Z15***

Z18***, XZ18***

613 mm

131 mm

16 mm

360.5 mm

A

B

C

D

1. 

Remove the control board cover from the unit by loosening the screw.

2. 

Connection cable

 between indoor unit and outdoor unit shall be 

approved polychloroprene sheathed 4 x 1.5 mm

2

 (3/4 ~ 1.75HP) or 4 x 

2.5 mm

2

 (2.0HP) fl exible cord, type designation 60245 IEC 57 or heavier 

cord. Do not use joint connection cable. Replace the wire if the existing 
wire (from concealed wiring, or otherwise) is too short.

Terminals on the outdoor unit

S1

2

3

Colour of wires (connection cable)

Terminals on the indoor unit

L

1

N

S1

2

3

3. 

Secure the cable onto the control board with the holder (clamper).

4. 

Attach the control board cover back to the original position with screw.

5. 

For wire stripping and connection requirement, refer to instruction 

5

 of 

indoor unit.

AIR PURGING METHOD IS PROHIBITED FOR R32 SYSTEM

WARNING

RISK OF FIRE

JOINING OF 
WIRES MAY 
CAUSE 
OVERHEATING 
AND FIRE.

  Do not joint wires

OR

OR

  Use complete wire without joining.

  Use approved socket and plug with earth pin.

   Wire connection in this area must follow to national 

wiring rules.

WIRE STRIPPING, CONNECTING 
REQUIREMENT

Wire stripping

No loose strand 
when inserted

10 ± 1 mm

5 mm or more

Indoor/outdoor 
connection 
terminal board

(gap between wires)

Conductor 

fully inserted

Conductor over 

inserted

Conductor not 

fully inserted

ACCEPT

PROHIBITED

PROHIBITED

3

4

B

A

C

Wall

Wall

Wall

Installation plate 

1

2

 screw

More than 

1

More than 

1

Measuring 
Tape

Indoor unit

266 mm

128 mm

266 mm

128 mm

More than 

2

For best strength of 
INDOOR unit installation, 
it is highly recommended 
to locate “ ” at 5 position 
as shown.

PIPE 

HOLE 

CENTER

PIPE 

HOLE 

CENTER

128mm TO 

PIPE HOLE 

CENTER

128mm TO 

PIPE HOLE 

CENTER

Hose

Install the hose at an angle so that the 
water smoothly fl ows out.

Drain elbow

 

7

CHECK THE DRAINAGE

 

Open front panel and remove air fi lters.
(Drainage checking can be carried out without removing the front grille.)

 

Pour a glass of water into the drain tray-styrofoam.

 

Ensure that water fl ows out from drain hose of the indoor unit.

Drain tray-styrofoam

EVALUATION OF THE PERFORMANCE

 

Operate the unit at cooling/heating operation mode for fi fteen minutes or more.

 

Measure the temperature of the intake and discharge air.

 

Ensure the difference between the intake temperature and the discharge is more 
than 8°C during Cooling operation or more than 14°C during Heating operation.

Discharge air

Secure the power supply cord and connection cable onto 
the control board with the holder.

Close grille door by tighten with screw and close the 
front panel.

Holder

Indoor unit

Indoor & outdoor 
connection cable

Earth wire 
longer than 
others 
AC wires 
for safety 
reason

Terminal Board

Exchange the drain hose and 
the cap

CONNECT THE PIPING

3

Connecting The Piping to Indoor

For connection joint location at outside building

Please make flare after inserting flare nut (locate at joint 
portion of tube assembly) onto the copper pipe. (In case of 
using long piping)

Connect the piping

 

Align the center of piping and suffi ciently tighten the fl are 
nut with fi ngers.

 

Further tighten the fl are nut with torque wrench in specifi ed 
torque as stated in the table.

Torque 
wrench

Spanner or 
Wrench

For connection joint location at inside building

 

Decide the length.

 

Cut and remove the tube connectors at indoor copper pipings 
(both gas and liquid piping) by using pipe cutter. Remove burrs 
from cut edge.

 

Use pipe expander to expand the end of long piping.

 

Align the center of piping and braze the piping joints.

Indoor 
copper pipe

Tube connector

(40~50mm)

Brazing point

1. Cut and 

Remove

2. Expand long 

pipe

3. Braze both 

pipe

Connecting The Piping to Outdoor

Decide piping length and then cut by using pipe cutter.
Remove burrs from cut edge.
Make fl are after inserting the fl are nut (locate at valve) 
onto the copper pipe. Align center of piping to valve and 
then tighten with torque wrench to the specifi ed torque as 
stated in the table.

ECO SENSOR

Do not overtighten, overtightening may cause gas leakage.

Piping size

Torque

6.35 mm (1/4")

[18 N•m (1.8 kgf•m)]

9.52 mm (3/8")

[42 N•m (4.3 kgf•m)]

12.7 mm (1/2")

[55 N•m (5.6 kgf•m)]

15.88 mm (5/8")

[65 N•m (6.6 kgf•m)]

19.05 mm (3/4")

[100 N•m (10.2 kgf•m)]

Vane

(Move the vane 
to downward)

Screw

Front 
grille

Cap

Содержание Z7 SERIES

Страница 1: ...equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of lea...

Страница 2: ...using anchor bolts Always mount the installation plate horizontally by aligning the marking off line with the thread and using a level gauge 2 Drill the piping plate hole with 70 mm hole core drill Li...

Страница 3: ...iciente Se debe informar al propietario del equipo para que todas las partes est n avisadas en adelante 3 Reparaciones de componentes sellados Durante las reparaciones de componentes sellados se deben...

Страница 4: ...nos de anclaje Coloque siempre la l mina de instalaci n horizontalmente alineando la l nea de demarcaci n utilizando un nivel 2 Perfore el hueco de la placa de tuber a con un taladro de broca de 70 mm...

Страница 5: ...anea Il proprietario del materiale deve essere informato o avvisato in modo che possa avvisare tutti 3 Riparazioni ai componenti sigillati Durante le riparazioni ai componenti sigillate scollegare tut...

Страница 6: ...si a circa 6 da questa linea 1 Montare la piastra di installazione sulla parete con le 5 viti o pi almeno 5 viti Se l apparecchio viene montato su muro in calcestruzzo usare bulloni di ancoraggio Mont...

Страница 7: ...zijn ge nformeerd 3 Reparatie aan afgedichte onderdelen Tijdens reparaties aan afgedichte onderdelen moeten alle elektrische voedingen worden losgekoppeld van de apparatuur waaraan gewerkt wordt voord...

Страница 8: ...ven Indien het toestel op een betonnen muur wordt bevestigd dient u het gebruik van ankerbouten te overwegen Bevestig de installatieplaat steeds horizontaal Gebruik een schietlood en een waterpas 2 Bo...

Страница 9: ...ormado ou deve ser efetuado um relat rio para que todas as partes sejam informadas doravante 3 Repara es dos componentes selados Durante as repara es de componentes selados a corrente el trica deve se...

Страница 10: ...nidade numa parede de bet o considere a utiliza o de parafusos de ancoragem Monte sempre a placa de instala o horizontalmente alinhando a linha de marca o com as porcas e utilizando um nivel 2 Fa a o...

Страница 11: ...4 mm 5 6 7 8 9 10 11 12 13 14 18 N m 1 8 kgf m 42 N m 4 3 kgf m 55 N m 5 6 kgf m 65 N m 6 6 kgf m 100 N m 10 2 kgf m 15 16 1 3 4 1 4 2 7 1 2 5 5 1 3 1 6 2 CZ 3F5 7BP 9 52 mm 3 8 6 35 mm 1 4 CZ 4F5 7...

Страница 12: ...4 1 2 3 4 5 6 Z7 XZ7 Z9 XZ9 Z12 XZ12 Z15 Z18 XZ18 515 mm 82 mm 460 mm 460 mm 43 mm 95 mm 1 2 3 1 2 3 0 0 5 mm 70 80m m 1 2 POLY E FOAM 6 mm 1 3 2 3 0 cmHg 0 MPa 76 cmHg 0 1 MPa 4 5 3 6 3 18 N m 7 2 3...

Страница 13: ...01990 AB 1 1 2 3 70 4 4 5 6 7 8 9 10 11 12 13 14 18 1 8 42 4 3 55 5 6 65 6 6 100 10 2 15 16 1 3 4 1 4 2 7 1 2 5 5 1 3 1 6 2 CZ 3F5 7BP 9 52 3 8 6 35 1 4 CZ 4F5 7 10BP 12 7 1 2 6 35 1 4 CZ 52F5 7 10BP...

Страница 14: ...4 b 5 6 1 5 5 2 70 128 1 2 3 15 4 15 70 5 7 5 2 1 2 4 6 5 4 1 2 3 4 5 6 Z7 XZ7 Z9 XZ9 Z12 XZ12 Z15 Z18 XZ18 515 82 460 460 43 95 1 2 3 1 2 3 0 0 5 70 80 1 2 POLY E FOAM 6 1 3 2 3 0 c Hg 0 MPa 76 c Hg...

Страница 15: ...mpl te r solution Si le d faut ne peut pas tre imm diatement corrig mais qu il est n cessaire de poursuivre le fonctionnement une solution temporaire ad quate doit tre utilis e Le propri taire de l qu...

Страница 16: ...entre le centre de la plaque d installation et le bord droit de I unit est de 4 b Pour la conduite gauche le raccordement du liquide doit se trouve 5 environ de cette ligne Pour la conduite gauche le...

Страница 17: ...en Der Besitzer der Ausr stung muss informiert werden damit anschlie end alle Beteiligten Bescheid wissen 3 Reparaturen an versiegelten Bauteilen W hrend der Reparaturen an versiegelten Bauteilen m ss...

Страница 18: ...dorts 1 INSTALLATION DES AUSSENGER TS EVAKUIEREN DER ANLAGE ROHRD MMSTOFF 2 4 6 KABELANSCHLUSS AM AUSSENGER T 5 MONTAGE DES INNENGER TS 4 Modell Abmessungen 1 2 3 4 5 6 Z7 XZ7 Z9 XZ9 Z12 XZ12 Z15 Z18...

Страница 19: ...te sve strane 3 Popravak zabrtvljenih komponenti Tijekom popravki zabrtvljenih komponenti svi elektri ni dovodi se moraju odspojiti od opreme na kojoj se radi prije skidanja svih zabrtvljenih poklopac...

Страница 20: ...enu liniju s navojem i pomo u mjerila za razinu 2 Izbu ite otvor nosa a voda s nareznim svrdlom 70 mm Poravnajte prema lijevoj i desnoj strani metalnog nosa a To ka sjeci ta produljene linije je sred...

Страница 21: ...lemleri s ras nda t m g kaynaklar n n ba lant s m h rl herhangi bir kapak kar lmadan nce vb al an ekipmandan kesilmelidir Hizmete alma i lemi s ras nda ekipmanda bir g kayna n n olmas kesinlikle gerek...

Страница 22: ...n duvara 5 ya da daha fazla vida ile monte edin en az 5 vida E er birim beton duvara monte ediliyorsa ba lant c vatalar kullanmay g z n nde bulundurun Kurulum plakas n her zaman tel ile s n r izgisi h...

Отзывы: