Settings
22
※
3 P21
和
P22
(
BURNBACK TIME 1 and BURNBACK TIME 2
)
It is the duration of time (short period of time) to keep supplying output voltage after stopping the arc by turning
offthe torch switch. (It is to burn up excess wire fed out of the end of the torch tip
due to inertia of the wire feed motor.
【
Pulse-OFF
】
【
Pulse-ON
】
P22
P21
P21
P22
【
Arc control
】
NO.
Menu contents
Set range
Increment
Default
Note
P01
Arc ignition
energy
compensation
-50
~
50
1
0
Fine adjustment of peak current of arc.
It increases when the direction is adjusted
positive value.
P02
Arc ignition
voltage
compensation
-5
~
5
1
0.1
Fine adjustment of the arc voltage value.
The peak current of the arc is increased
when the direction is adjusted positive
value.
P03
Arc ignition time
compensation
-50
~
50
1
0
The role of micro-adjustment of the arc
voltage.
Positive value direction of the arc voltage
adjustment time longer.
【
Pulse control
】
NO.
Menu contents
Set range
Increment
Default
Note
P15
Dual-pulse
frequency
※
5
-5 Hz
~
5 Hz
0.1Hz
0
P16
Low pulse
duty ratio
-50
~
50
1
50
the second pulse output duty ratio.
P17
Low pulse
current
-50
~
200
1
120
Low pulse current set point.
P18
low pulse
voltage
-9.9V
~
9.9V
0.1V
0V
Voltage compensation for the unified voltage.
Содержание YD-350FD2
Страница 9: ...Rated Specifications 6 2 4 Dimensions 机型 W H L YD 350FD2HGY 570 1060 1200 YD 500FD2HGY ...
Страница 30: ...Operation 27 9 2 CRATER Operation Turn the torch switch on and off twice ...
Страница 42: ...Parts list 39 Right view Left view 1 3 11 12 13 15 16 43 48 51 52 53 56 35 2 4 5 6 7 8 9 10 14 26 54 55 40 ...
Страница 45: ...Circuit diagram 42 13Circuit diagram 13 1 Circuit diagram for YD 350FD2HGY ...
Страница 46: ...Circuit diagram 43 13 2 Circuit diagram for YD 500FD2HGY ...