Troubleshooting
OMCTT5621E18
49
11.2 Troubleshooting table
* In the case of welding errors without any error (Err) indication, refer to the following table to search for their causes.
Error
condition
Front panel display is not turned on
Neither high frequency wave nor arc is generated.
High frequency wave is generated without arc.
Bead turns black.
Lack of arc occurs.
Insufficient arc start
No gas supply
Gas flows without stop
Check item
Probable causes
Distribution box
(Input protection device)
• Switch is not ON.
• Blown fuse.
• Tripping of circuit breaker.
• Loose connections.
O
O
O
Input cable
• Cable is disconnected or severed.
• Loose connections.
• No phase.
O
O
O
Switches
• Switch is not ON.
O
O
O
• “GAS” switch is placed to “Purge”.
O
Gas cylinder and
Gas regulator
• Main cock is not open.
• Gas nearly runs short.
• Insufficient flow rate.
O
O
O
O
O
• Excessive flow rate.
O
O
Gas hose (From gas cylin
-
der to torch.)
• Loose connections
• Hose is damaged.
O
O
Torch cable
• Torch is bent at acute angle.
• Coating is damaged.
• Sign of insulation deterioration.
O
O
O
• Torch switch is not ON.
O
Around the torch body
• Insufficient fastening of the collet.
• Sizes of collet body, collet and electrode
do not match.
• Insufficient fastening of the torch body.
O
O
• Attach an earth ring ass’y.
O
Cables on the base metal
• Insufficient cable size (sectional area.)
• Loose connections
• Poorly energized base metal.
O
O
O
Welding conditions
• Check torch angle, distance between
electrode and base metal once again.
O
O
O
O
Default settings
• Try to set “
Hot Cur Level
” to “High”
O
High frequency board
• High-frequency gap (electrode surface)
is dirty.
O
Содержание YC-300BZ3YHD
Страница 50: ...Parts list OMCTT5621E18 50 12 Parts list ...
Страница 52: ...Circuit diagram OMCTT5621E18 52 13 Circuit diagram ...
Страница 53: ...Circuit diagram OMCTT5621E18 53 ...
Страница 59: ...OMCTT5621E18 59 ...