Guide for Getting FPC connector Y5B and Y5BW
Panasonic Corporation
industrial.panasonic.com/ac/e/
©
Panasonic Corporation 2015
ACCTF15E-3 201507
- 13 -
07. Precautions for mounting and reflow soldering
07-1. Points to consider when selecting a pickup nozzle
for mounting
Select a pickup nozzle with a suction area that demonstrates a theoretical lifting force
at least
10 times
greater than the connector weight. .
Theoretical lifting force (g) = Vacuum pressure (mmHG) /760 x 1.033 x Nozzle area
(cm
2
)
Example of machine vacuum pressure setting: 480–520 mmHg
■
Picking up the connector
(1) The suction area on the connector is 1.60 mm in the shorter direction.
(2) When picking up the connector, please pay attention that the nozzle do not touch
the lever. Make sure that the nozzle is in the right place. Otherwise, it may cause
suction failure.
●
Nozzle examples
●
Single connector weight
Y5B
Y5BW
Weight
4 pins
2 pins
0.02 g
12 pins
10 pins
0.05 g
24 pins
22 pins
0.08 g
50 pins
48 pins
0.16 g
1. Elongated hole
Pay attention that
the nozzle do not
touch the lever.
2. Circular hole
There
is
difference
in
connector’s speed of moving
or rolling.