background image

5

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

Front View

1

2

3

4

5

6

7

8

9

MON

CAM

ESC

SET

0

ACK

RESET

BACK

SEQ

FORWARD

SEQ

ALT

DEC

–1CAM

INC

+1CAM STOP

SLOW

1

2

AUX

CLOSE

OPEN

IRIS

PRESET

FOCUS

NEAR

ZOOM

TELE

FAR

WIDE

System Controller WV-CU

550

LEFT

RIGHT

UP

DOWN

ALARM

BUSY

F3

F4

F2

F1

B

AF

q

w

e

r

t

y

u

i

o

!0

!1

!2

!3

!4

!5

!6

!7

@1

!9

!8

@0

CONTROLLER

ON

OFF

IN

OUT

TERM

ON

OFF

DATA

0 1

2

3

45

6

7

8

9

CONTROLLER

UNIT NO.

1-8

MODE

#1

#2

#3

#4

#5

#6

Rear View

Содержание WVCU550B - SYSTEM CONTROLLER

Страница 1: ...manual for future use Model No WV CU550B System Controller Operating Instructions ALARM ACK RESET AUX DEC 1CAM INC 1CAM STOP SLOW ESC SET MON CAM WIDE FAR ZOOM TELE FOCUS NEAR RESET IRIS 1 2 3 4 5 6 7 8 0 9 CLOSE OPEN 1 2 BACK SEQ FOWARD SEQ ALT BUSY LEFT System Controller WV CU550B RIGHT UP DOWN F1 F2 F3 F4 ...

Страница 2: ...s equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Caution To assure continued compliance example use only shielded interface cables when connecting to com puter or peripheral devices Any changes or modifications not expressly approved by the party responsible for compli ance could voi...

Страница 3: ...one of 16 monitors Remote control of up to 128 cameras and auxiliary equipment by using optional receivers and accessories including 1 Remote control of Pan Tilt Head and Camera Housing 2 Remote control of Motorized Zoom Lenses Focus Zoom and Iris 3 Remote control of camera settings including Electronic Sensitivity Enhancement Electronic Shutter Electronic Zoom and more Selection of various sequen...

Страница 4: ... nor try to operate it in wet areas Take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified ser vice personnel Moisture may damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the appliance when it is dirty When the dirt is hard to remove use a mild deter...

Страница 5: ...EQ ALT DEC 1CAM INC 1CAM STOP SLOW 1 2 AUX CLOSE OPEN IRIS PRESET FOCUS NEAR ZOOM TELE FAR WIDE System Controller WV CU 550 LEFT RIGHT UP DOWN ALARM BUSY F3 F4 F2 F1 B AF q w e r t y u i o 0 1 2 3 4 5 6 7 1 9 8 0 CONTROLLER ON OFF IN OUT TERM ON OFF DATA 0 1 2 3 4 5 6 7 8 9 CONTROLLER UNIT NO 1 8 MODE 1 2 3 4 5 6 Rear View ...

Страница 6: ...the desired camera number with the Numeric keys and then press the CAM key SET This key in combination with the Numeric keys is used to enter numeric input such as operator ID and password It is also used to execute the currently highlighted selection and to enter a submenu in the Setup Menu of the Matrix Switcher 2 Numeric Keys 0 9 These keys are used for numeric input into the system such as the...

Страница 7: ...edgment the indicator on the button blinks rapidly and finally press it again for alarm reset the indicator goes off After an alarm acknowledgment pressing this button while the Alternate ALT indicator is on will cancel all currently activated alarms at the same time 1 Data Ports DATA IN OUT Exchanges control data with the WJ SX550B Matrix Switcher in a system 2 Termination Switch TERM ON OFF This...

Страница 8: ... Controller by removing four screws 2 Remove the Palm rest located on the front of the System Controller by removing two screws 3 Place the Rack Mounting Brackets on both sides of the System Controller and tighten with the four supplied screws 4 Install the System Controller with Rack Mounting Brackets in the rack by using four screws procured locally Remove screws Tighten screws Rack Mounting Bra...

Страница 9: ...o Preset Off Lens Functions Iris Open Close Preset only with DC control lens Focus Near Far Zoom Tele Wide Auto Focus Activate Housing Wiper On Off Defroster On Off Camera On Off Pan Tilt Manual Pan Right Left Manual Tilt Up Down Auto Pan On off Random Pan On Off Preset Home Auxiliary Switch AUX 1 2 On Off Unit Number 1 8 Ambient Operating Temperature 10 C 50 C 14 F 122 F Ambient Operating Humidit...

Страница 10: ...et STANDARD ACCESSORY Matrix Switcher WJ SX550B Extension Unit WJ AD550 Video Input Board WV PB5508 Video Output Board WV PB5504A Alarm Board WV PB5564 Data Board WV PB5548 Rack Mounting Bracket WV Q62 Blank Panel WV Q63 MAJOR OPTIONAL UNITS AND ACCESSORIES ...

Страница 11: ...onic Security and Digital Imaging Systems Company A Division of Matsushita Electric Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Midwest 1707 North Randall Road Elgin IL 60123 847 468 5211 Western 6550 Kat...