[Intensity control]
U254x
U253x
U214x
U213x
U154x
U153x
Select On/Off to determine whether or not to activate the IR Light over exposure suppression function.
•
Default:
Off
White balance
[White balance]
Select a method of white balance adjustment from the following.
White color can be adjusted by “Red gain” and “Blue gain”.
•
ATW1:
Selects the automatic tracing white balance mode. The camera will constantly check the color
temperature of the light source and adjust the white balance automatically. Operating color temperature
range is approx. 2,700 K to 6,000 K.
•
ATW2:
Selects the automatic tracing white balance mode under a sodium lamp. The camera will adjust
the white balance automatically under a sodium lamp. Operating color temperature range is approx. 2,000
K to 6,000 K.
•
AWC:
Selects the automatic white balance control mode. This adjustment is suitable for a location where
a light source is stable. Operating color temperature range is approx. 2,000 K to 10,000 K.
•
Default:
ATW1
Note
•
Under the following conditions, color may not be faithfully processed. In these cases, select “AWC”.
–
When shooting a subject whose major part is a thick color
–
When shooting blue sky or sun at sunset
–
When shooting a subject whose luminance is too low
•
When “AWC” is selected, click the [Set] button.
[Red gain]
Adjust the red color of images.
When the slider is moved in the “+” direction, the red color will become thicker. When the slider is moved in
the “-” direction, the red color will be thinner. Click the [Reset] button to reset the color to the default.
•
Default:
128
[Blue gain]
Adjust the blue color of images.
When the slider is moved in the “+” direction, the blue color will become thicker. When the slider is moved in
the “-” direction, the blue color will be thinner. Click the [Reset] button to reset the color to the default.
•
Default:
128
Intelligent auto