13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence or
alarm images, the VMD area settings, audio detection settings, and the alarm occurrence notification can be
configured on this page.
The “Alarm” page has the [Alarm] tab, the [VMD area] tab, the [Audio detection] tab, and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
®
page 40, page 42)
The settings relating to the alarm can be configured in this section. Refer to page 118 and page 116 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
Determine how to use terminal 1.
•
Off:
Not used.
•
Alarm input:
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close” and
“Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
•
Black & white input:
Receives the black & white switchover input. (When the input is set to On, the black
& white mode is activated.)
•
Default:
Off
[Terminal 2]
Determine how to use terminal 2.
•
Off:
Not used.
•
Alarm input:
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close” and
“Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
Operating Instructions
115
13 Configure the alarm settings [Alarm]
Содержание WV-SFN611L
Страница 173: ...8 Click Next 9 Click Finish Operating Instructions 173 16 Configuring the network settings Network ...
Страница 213: ...Operating Instructions 213 Notes ...
Страница 214: ...214 Operating Instructions Notes ...
Страница 215: ...Operating Instructions 215 Notes ...