-3-
3. Confirm switchers (SW12) on the board are set to the following positions.
12
OFF
SW12
These switches are used only for factory test.
Always keep these switches in the "OFF" positions in the
field.
Note
2. Set switches (SW4 - SW11) on the board to meet the
alarm input requirements. Initially, normally open
(NOR, OPEN) positions are selected at the factory.
1
2
3
4
5
6
7
8
OFF
SW4
NOR
CLOSE
NOR
OPEN
1
1
2
3
4
5
6
7
8
OFF
SW5
2
1
2
3
4
5
6
7
8
SW4
SW5
SW6
SW7
SW8
SW9
SW10
SW11
Switch No.
1 - 8 (65-72)
9 - 16 (73-80)
17 - 24 (81-88)
25 - 32 (89-96)
33 - 40 (97-104)
41 - 48 (105-112)
49 - 56 (113-120)
57 - 64 (121-128)
Alarm Input
1
12
OFF
SW1
12
OFF
SW12
UNIT ADR
SW4
2
SW5
3
SW6
4
SW7
5
SW8
6
SW9
7
SW10
8
SW11
The following installation should be made by qualified ser-
vice personnel or system installers.
1. Remove the screws from the rear panel(s) of the
Matrix Switcher.
2. Remove the rear panel(s).
3. Place the Alarm Board into the desired position in the
rear of Matrix Switcher by sliding it inside the board
quides.
INSTALLATION
Before installing this board be sure to turn off the Power
Switch of the Matrix Switcher.
Caution
Each slot is identical, so the board can installed in any
slot.
However it is recommended to install the board as
shown below for an orderly installation.
Note
Rear Panel(s)
Remove screws.