Alarm Board

WV-PB5564E

Before attempting to connect or operate this product, please read these instructions completely

PREFACE

The WV-PB5564E Alarm Board is provided for expanding the system capability of the Matrix
Switcher.

When handling this board, hold only by circuit board edges. Otherwise components on the
board may be damaged by static electricity.

Caution

APPEARANCE

1.

Alarm Number display

This display indicates the alarm input number when the associated alarm sensor unit is activat-
ed.

Note:

The display indicator lights up as shown below When the alarm number is over one hun-

dred.

2.

Mode Selection Switch (MODE)

This rotary switch, in combination with the test switch, is used to select the alarm test mode.

Mode 0:

Press the Test Switch to receive, from memory, a chronologically organized display (in

the Alarm Number Display) of all alarms received from the Alarm Input Connector.

Mode 1:

Press the Test Switch to simulate receiving alarm inputs 1-64 in ascending order, one

alarm per second. Use this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3
set up.

Mode 2:

Press the Test Switch to simulate receiving alarm inputs 1-64 all at the same time. Use

this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3 set up.

Mode 3-9:

These modes are not available.

Note:

The alarm inputs 65-128 are activated above modes if the SW1 on the board is set at

alarm number 65-128. Refer to the BOARD SETTING on page 2.

3.

Test Switch (TEST)

This switch is used to run the alarm test mode in combination with the Mode Selection Switch.

4.

Reset Switch (RESET)

This switch is used to stop the alarm test mode or clear alarm the records from the internal
memory.

33-64

ALARM

TEST

1-32

00

5

RESET

MODE

q

w

e

r

t

0 0

indicator

Содержание WV-PB5564E

Страница 1: ...rom memory a chronologically organized display in the Alarm Number Display of all alarms received from the Alarm Input Connector Mode 1 Press the Test Switch to simulate receiving alarm inputs 1 64 in ascending order one alarm per second Use this mode to test the system for Alarm Mode 1 Mode 2 or Mode 3 set up Mode 2 Press the Test Switch to simulate receiving alarm inputs 1 64 all at the same tim...

Страница 2: ... Alarm 33 97 Alarm 34 98 Alarm 35 99 Alarm 36 100 Alarm 37 101 Alarm 38 102 Alarm 39 103 Alarm 40 104 Alarm 41 105 Alarm 42 106 Alarm 43 107 Alarm 44 108 Alarm 45 109 Alarm 46 110 Alarm 47 111 Alarm 48 112 Alarm 49 113 Alarm 50 114 Alarm 51 115 Designation 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Pin No Alarm 52 116 Alarm 53 117 Alarm 54 118 Alarm 55 119 Alarm 56 120 Alarm 57 121 Alar...

Страница 3: ...41 48 105 112 49 56 113 120 57 64 121 128 Alarm Input 1 1 2 OFF SW1 1 2 OFF SW12 UNIT ADR SW4 2 SW5 3 SW6 4 SW7 5 SW8 6 SW9 7 SW10 8 SW11 The following installation should be made by qualified ser vice personnel or system installers 1 Remove the screws from the rear panel s of the Matrix Switcher 2 Remove the rear panel s 3 Place the Alarm Board into the desired position in the rear of Matrix Swit...

Страница 4: ...Board WV PB5564 Video Input Board Video Output Board CPU RS 232C TIME ADJUST IN COM PRINTER OUT IN VS VD VD OUT OFF 9V 5V 5V POWER ON 11A00001 OUT IN 1 OUT IN 2 OUT IN 3 OUT IN 4 MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN OUTPUT MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN MONITOR ALARM OUT RESET OUT EXT TIMING IN RECOVER IN OU...

Отзывы: