Mounting the Lens

Caution:

Before you mount the lens, loosen the screw on the side of the camera, and rotate the
frange-back adjusting ring clockwise until it stops.  If the ring is not at the end, the inner
glass or CCD image sensor may be
damaged.

1. Mount the lens by turning it clockwise

on the lens mount of the camera.

2. Connect the lens cable to the auto iris

lens connector on the side of the cam-
era.

Caution for Mounting the Lens

The lens mount should be a CS-mount (1”-32UN) and the lens weight should be less than
450 

g

(0.99 lbs).  If the lens is heavier, both the lens and camera should be secured by

using the supporter.
The protrusion at the rear of the lens should be as shown below:

CS-mount: Less than 8 mm (5/16”)

The following adjustment should be made by qualified service personnel or system
installers.

1. Loosen the screw on the side of the

camera.

2. Turn the flange-back adjusting ring to

the desired position.

Caution:

Do not rotate the ring coun-

terclockwise by force after it stops.
If the ring is rotated by force, the
inner lens or CCD image sensor
may be damaged.

3. Tighten the screw on the side of the

camera.

Cautions:

• Tightening the screw by force will cause damage to the screw or deviation of

focus.

• To use the C-mount lens, the Lens Mount Converter (C-mount adapter) WV-AD20

should be used with the camera.

FOCUS OR FLANGE-BACK ADJUSTMENT

ALC Connector

Screw

Flange-back
Adjusting Ring

Flange-back
Adjusting Ring

Screw

CONNECTIONS

Caution:

Keep the POWER switch of the specified monitor, Camera Extension Unit and

Camera Drive Unit in OFF position while making connections. If the power of these units
is ON during connections, the camera does not function due to the built-in protection
circuit which protects it against wrong connections.

Basic System

Connect the coaxial cables between the camera and CAMERA IN connector of the
specified monitor or Camera Drive Unit. The approximate maximum cable length is as
follows:

Coaxial

Maximum

DC R/300 m (1 000 ft) of

Cable Type

Cable Length

Inner Conductor

RG-59/U

200 m (660 ft)

Less than 30 

RG-6/U

500 m (1 650 ft)

Less than 12 

The maximum DC resistance between the camera and these unit is 20 

.

Super Dynamic

Super Dynamic

Super Dynamic

Super Dynamic

Colour Monitor 
WV-CM143 
(Rear Panel)

Coaxial Cable

Coaxial Cable

Coaxial Cable

Coaxial Cable

Cameras

4

3

2

1

CAMERA INPUT

VIDEO OUT  VIDEO IN

AUDIO OUT AUDIO IN

OUT

TIMING SELECT

IN

REMOTE OUT

ALARM

CONTROL

SPOT MONITOR CONTROL IN

4

3

2

1

RESET

GND

ALL

MODE

STDBY

4

3

2

1

GND

RECOVER

CAMERA

EXTENSION IN

FOCUS

CAMERA  POWER

ON

OFF

Содержание WV-CP160E

Страница 1: ...or at dette produkt som denne deklaration omhandler er i overensstemmelse med standarder eller andre normative dokumenter i følge bestemmelserne i direktiv 89 336 EEC Vi deklarerar härmed värt fulla ansvar för att den produkt till vilken denna deklaration hänvisar är i överensstäm melse med standarddokument eller andra normativa dokument som framställs i EEC direktiv nr 89 336 Ilmoitamme yksinomai...

Страница 2: ...k a qualified service person for servicing Moisture can damage the camera and also create the danger of electric shock 4 Do not use strong or abrasive detergents when cleaning the camera body Use a dry cloth to clean the camera when dirty In case the dirt is hard to remove use a mild detergent and wipe gently PRECAUTIONS MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS q Auto Iris Lens Connector This ...

Страница 3: ...nput connector of the monitor 8 Rear Cover The rear cover can be removed to gain access to the terminal 6 High quality picture a 2H type vertical enhancer for greater picture sharpness b Chroma averaging circuit for better colour signal to noise ratio c Minimum of aliasing on fine objects d Expanded dynamic range by use of knee circuit e Highlight aperture correction for greater picture detail of ...

Страница 4: ...e damage to the screw or deviation of focus To use the C mount lens the Lens Mount Converter C mount adapter WV AD20 should be used with the camera FOCUS OR FLANGE BACK ADJUSTMENT ALC Connector Screw Flange back Adjusting Ring Flange back Adjusting Ring Screw CONNECTIONS Caution Keep the POWER switch of the specified monitor Camera Extension Unit and Camera Drive Unit in OFF position while making ...

Страница 5: ...unt the camera on the mounting bracket Make sure that the two original fixing screws are used when mounting the mount adapter as longer length screws may dam age inner components INSTALLATION OF CAMERA 3 Connect the camera and monitor with the coaxial cable and turn on the power switch of the monitor 4 While viewing the monitor picture loosen the angular control screw slight ly Adjust the camera s...

Страница 6: ... about the correct settings Proceed as follows 1 Make sure that the CAM SET UP menu is not displayed a camera picture is displayed 2 While pressing both and press for a few seconds The message ALL RESET momentarily appears on the monitor This resets all adjustments and parameters to the factory default settings Editing the CAM SET UP Menu Important Notice When the SET UP DISABLE appears in the bot...

Страница 7: ... assign a name to the camera The camera ID consists of up to 16 alphanumeric characters The camera ID display can be selected on or off on the monitor screen To edit the CAMERA ID 1 Move the cursor to the CAMERA ID parameter 2 Press The CAMERA ID menu appears The cursor on the letter 0 is highlighted 3 Move the cursor to the character you want to edit by pressing 4 After selecting the character pr...

Страница 8: ...N or fixed level OFF Note If ON is selected for the AGC para meter the noise reduction function is automatically activated under low light conditions to reduce noise In pictures containing a moving object this may result in an afterimage 5 Electronic Sensitivity Enhancement SENS UP There are two modes for SENS UP AUTO If you select X10 AUTO for example the sensitivity is raised automatically to X1...

Страница 9: ...nt to adjust the white balance manually press to select AWC and press The AWC menu appears on the monitor When ATW is selected press ing displays the ATW menu Fine Adjustment for AWC ATW Manually You can add the detailed setting for white balance setting manually 1 To set MASK SET proceed as described in steps 2 to 4 of ALC mode with SUPER D2 OFF and ELC mode 2 Move the cursor to R 3 Press or to o...

Страница 10: ...or SOFT SHARP on the side of the camera 1 Move the cursor to the AP SHARP AP SOFT parameter 2 While observing the colour video monitor move the I cursor to adjust the aperture gain level 8 4 Pedestal Level Setting PEDESTAL 1 Move the cursor to the PEDESTAL parameter 2 While observing the waveform monitor or colour video monitor move the I cursor to adjust the pedestal level black level To reset to...

Страница 11: ...tter Speed 1 50 OFF 1 120 1 250 1 500 1 1 000 1 2 000 1 4 000 1 10 000 s selectable Lens Mount CS mount ALC Lens DC drive Ambient Operating Temperature 10 C 50 C 14 F 122 F Ambient Operating Humidity Less than 90 Power Source From the specified monitor or camera drive unit Power Consumption 350 mA Dimensions without lens 68 W x 65 H x 126 D mm 2 11 16 W x 2 9 16 H x 4 15 16 D Weights without lens ...

Страница 12: ...Matsushita Electric Industrial Co Ltd Central P O Box 288 Osaka 530 91 Japan 2000 Matsushita Communication Industrial Co Ltd All rights reserved ...

Отзывы: