48
Note:
Holding down the right and left buttons for more than 2 seconds simultaneously restores
the settings of "CHROMA GAIN", "AP GAIN" and "PEDESTAL" to the default settings.
Flaw correction [PIX OFF]
Flaws in the displayed camera image are corrected. Up to 16 points can be corrected. Follow
the procedure below for flaw correction.
**SPECIAL SETUP**
CHROMA GAIN ...
|
...128
AP GAIN ...
|
...128
PEDESTAL ...
|
...128
- +
PIX OFF
COMMUNICATION COAX
CAMERA RESET PUSH SW
SER.NO. XXXXXXXX
RET TOP END
**PIX OFF**
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
000 000
RET TOP END
"SPECIAL SETUP" screen
"PIX OFF" screen
Flaw correction positioning screen
Step 1
Move the cursor to "PIX OFF" and press the setting button.
→
The "PIX OFF" screen appears.
Step 2
Select a number (1 to 16) with which a flaw correction point is registered and press the setting
button.
→
The flaw correction positioning screen appears.
Step 3
Use the up, down, right, and left buttons to move the crosshair cursor to the center of the flaw
to be corrected and press the setting button.
→
The flaw is corrected and the flaw correction point is registered. The "PIX OFF" screen
appears again. "
*
" is attached at the right side of the number when registration is complet-
ed. The coordinate is expressed in figures.