- 3 -
Configure the Settings Relating to Network
Configure and check the settings relating to network in the "IP address setting" window.
Note:
When opening this window for the first time, the factory default will be displayed. To check the current settings of system
controller, click "Load".
[IP (WV-CU950)]
Enter the IP address of system controller
as "nnn.nnn.nnn.nnn".
Available value for "nnn": 0 to 255
Default: 192.168.0.210
[Subnet mask]
Enter the subnet mask of system controller
as "nnn.nnn.nnn.nnn".
Available value for "nnn": 0 to 255
Default: 255.255.255.0
[Gateway]
Enter the gateway IP address of system controller as "nnn.nnn.nnn.nnn".
Available value for "nnn": 0 to 255
Default: 192.168.0.1
[IP (WV-ASM100)]
Enter the IP address of PC in which WV-ASM100 is installed.
Available value for "nnn": 0 to 255
Default: 192.168.0.200
[Keyboard ID]
Surely set the number to 01.
[Set] button
Saves the settings in the system controller.
[Load] button
Reads out the settings from the system controller.
When finishing the setup
Restart the system controller in the normal operation mode.
1. Click "Restart" in the "IP address setting" window.
"Connecting to Main CPU…" will appear on the LCD of system controller.
2. Click "Close". "IP address setting" window will disappear, and the screen returns to the "Serial port" window.
3. Click "Exit". You will exit the software.
Notes:
・
When a message other than "Connecting to Main CPU…" after the restart, check that the settings of MODE switches and
CONTROLLER NO. switch at the rear panel are as follows.
If the settings differ from the illustrations, turn off the system controller, set the switches, and turn on the system controller
again. Then, check that "Connecting to Main CPU…" appears on the LCD.
MODE
1
2
3
4
5
6
7
8
OFF
ON
CONTROLLER
NO.
0
9
8
7
6
5
4
3
2
1
・
After all the settings, disconnect the 9-pin D-sub cross cable from the system controller and PC.