Starting Up 

This software communicates with System Controller WV-CU950 via the RS-232C interface when setting the IP address of system 
controller or reading out the system controller setting. 
 
  1. Connect the system controller and PC with a 9-pin D-sub cross cable. 
 
  2. Select "Start" - "All Programs" - "Panasonic" - "WV-ASM100" - "WV-CU950 Setup Tool" or double-click the "WV-CU950 

Setup Tool" icon on the desktop. 

    System Controller WV-CU950 Setup Tool will start up, and the "Serial port" window will be displayed on the PC screen. 
 

 

 

Notes: 

 

  When clicking "Version information", the "Setup Tool" window will appear to display the software version. When clicking 

"OK", the screen returns to the "Serial port" window. 

 

  When clicking "Help", the "Help" window will appear. When clicking "OK", the screen returns to the "Serial port" window. 

 
  3. Select the number for "Port", and click "OK". "IP address setting" window will be displayed. 
 
  4. Turn on the power while holding down the button 7 and MON (ESC) button of system controller.   
    "Admin Password" entry form will appear on the LCD of system controller. 
 
  5. Enter the administrator password. (The factory default is "650".) Then, press the SET button. Short buzzer will sound three 

times, "GXCU-THRU-MODE" will appear on the LCD, and all the buttons in the "IP address setting" window will become 
available. 

 

 

 

Notes:  

 

  When returning from "IP address setting" window to the "Serial port" window, click "Close". 

 

  When such a communication error as cable disconnection happens, "Communication Error" window will appear. 

 

  Refer to the operating instructions of system controller for details on the administrator password. 

 
 

Содержание WV-ASM100

Страница 1: ... of CD ROM The installation wizard will be displayed on the PC screen 3 Click Next and follow the directions Notes It is required that Windows Installer 3 1 is installed on the PC to use this software In the factory default installation C Program Files Panasonic WV CU950 Setup Tool is created and files will be copied to the directory Uninstallation 1 Select Control Panel Add Remove Programs Add Re...

Страница 2: ... clicking Help the Help window will appear When clicking OK the screen returns to the Serial port window 3 Select the number for Port and click OK IP address setting window will be displayed 4 Turn on the power while holding down the button 7 and MON ESC button of system controller Admin Password entry form will appear on the LCD of system controller 5 Enter the administrator password The factory ...

Страница 3: ...urely set the number to 01 Set button Saves the settings in the system controller Load button Reads out the settings from the system controller When finishing the setup Restart the system controller in the normal operation mode 1 Click Restart in the IP address setting window Connecting to Main CPU will appear on the LCD of system controller 2 Click Close IP address setting window will disappear a...

Страница 4: ...ndal Road Elgin IL 60123 Southern 1225 Northbrook Parkway Suwanee GA 30024 Western 6550 Katella Ave Cypress CA 90630 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 Canada 905 624 5010 http www panasonic ca Panasonic Sales Company Division of Panasonic Puerto Rico Inc San Gabriel Industrial Park 65th Infantry Ave KM 9 5 Carolina P R 00985 809 750 4300 For European and other fiel...

Отзывы: