19
Chapter 2 General Settings
60 - 79
70
Auto Tone Adjust
If the coloured image tone has deviated,
set the automatic tone adjustment.
<Procedure>
1. Execute this mode to print the calibration
sheet.
2. Place the calibration sheet on the Platen
Glass and execute this mode again.
Stop, Start
Stop
71
Tone Adjust Reset
If “
70 Auto Tone Adjust
” has made the
original image tone indistinguishable,
execute this mode to reset the machine to
the factory default setting.
Stop, Start
Stop
72
EWS Output
Queue
Set whether to display the print job
information in the Output Queue on the
Status screen of the Embedded WEB.
• Up to 10 print jobs can be displayed.
Off, On
On
73
Administrator
Name
When “
75 User Authentication
” is set to
“
On
” and a local machine is selected as
domain, set administrator’s name and,
password for authentication.
Up to 40 characters
74
Authentication
Method
When “
75 User Authentication
” is set to
“
On
”, set the authentication method.
NTLM, Clr Text
NTLM
75
User
Authentication
Set whether to use User Authentication,
and then select for which functions.
Copy, Fax, Print,
Scan
(Off, On)
76
ID Timeout
When “
75 User Authentication
” is set to
“
On
”, set at what phase the machine will
require the authentication.
Auto Rst, EveryJob
Auto Rst
77
Log-on Attempts
When “
75 User Authentication
” is set to
“
On
”, set the number of permitted logon
attempts. (Set “0” for unlimited attempts.)
0 to 9
0
78
User Auth. Domain
When “
75 User Authentication
” is set to
“
On
”, set the domain for authentication.
The default port number is changed by the
SSL setting.
No. 00 to 09
“
SSL
”
Off: 389
On: 636
79
Lockout Time
When “
75 User Authentication
” is set to
“
On
”, set the lockout time.
If you failed to logon during specified times,
you cannot logon again during the lockout
time.
1 to 60 (min.)
5 (min.)
80 - 89
84
SD/PC Card
Function
Set whether to use SD/PC card.
No, Yes
Yes
85
Key Operator
Password
Set the 8-digit Key Operator Password.
Up to 8 characters
86
HD Drive Lock
Settings
Set the 32-digit HD Drive Lock password.
z
When the Set Drive Lock is selected.
The machine requires rebooting, and the
“Change Lock Password” and “Release
Drive Lock” tasks must be carried out.
Set Hard Drive Lock
Set Hard
Drive Lock
Key Operator Mode
No.
Parameter
Comments
Selective Item
Standard
Setting
Содержание Workio DP-C265
Страница 27: ...27 Chapter 2 General Settings Memo...
Страница 29: ...29 Chapter 2 General Settings Memo...
Страница 39: ...39 Chapter 3 Copier Settings Memo...
Страница 63: ...63 Chapter 4 Fax Email Settings Memo...
Страница 69: ...69 Chapter 4 Fax Email Settings Memo...
Страница 83: ...83 Chapter 4 Fax Email Settings Memo...
Страница 93: ...93 Chapter 6 Printer Settings Memo...