209
SEP 2004
Ver. 1.2
DP-1520P/1820P/1820E
012 DTMF Level
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
013 G3 RX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
015 ~
016
Not Used
017 TX Start
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
Selects the transmission modem start speed,
14400/12000/TC9600/TC7200/9600/7200/4800/
2400 bps.
Press “V” or “/\ “ to select the symbol rate.
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 32.
018 RX Start
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
Press “V” or “/\ “ to select the symbol rate.
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 33.
019 ITU-T V.34
1 = Off
2 = On
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
Select
: Select whether the ITU-T V.34 is Off or On,
when entering Phone Book Dialing
Numbers or Manual Number Dialing.
020 ITU-T ECM
1 = Off (Invalid)
2 = On (Valid)
Select the ECM mode.
021 EP Tone
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on
V.29 mode.
(Used when Echo Suppression is disabled.)
On
: Add
Off
: Do not add
022 Signal Interval
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving
signal and the transmitting signal.
023 TCF Check
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024 CED Frequency
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
025 COMM. Start-Up
1 = First
2 = Second
Selects the communication start-up condition (XMT
and Polling).
(Used when Echo Suppression is disabled.)
Function Parameter Table
No.
Parameter
Selections
Function
Содержание Workio DP-1820P
Страница 98: ...98 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E DETAIL A 28 35 31 32 33 34 30 29 ...
Страница 464: ...464 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E memo ...
Страница 465: ...88 Panasonic Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 DZSD001829 9 ...
Страница 480: ...Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 DZSD000965 14 ...
Страница 491: ...Local Firmware Update Tool Parallel USB Port 5b4 Firmware Code File selection is completed Click Next Page 12 ...
Страница 495: ...memo ...
Страница 496: ...DZZSM00257 ...