The ALARM MODE sub menu appears.
1. Move the cursor to MONITOR SPOT to select ON or
OFF with the [–] or [+] button. The default setting is ON.
This setting specifies whether to change the monitoring
image when an alarm operates.
ON:
The image displayed on the monitor screen
changes to that of the alarm activated channel.
OFF:
The image displayed will not change even when
an alarm operates.
2. Move the cursor to ALARM DISPLAY. Select ON or OFF
with the [–] or [+] button. The default setting is ON.
Alarm display “ALARM
***
” on the monitor is enabled
or disabled while an alarm is in operation. “
***
” is the
alarm channel number.
ON:
Enabled.
OFF:
Disabled.
3. Move the cursor to SITE ALARM. Select ON or OFF with
the [–] or [+] button. The default setting is ON.
A site alarm (motion detection) generated by a camera
is accepted or ignored.
ON:
Enabled.
OFF:
Disabled.
4. Move the cursor to TERM. ALARM (terminal alarm).
Select ON or OFF with the [–] or [+] button. The default
setting is ON.
An alarm input to the rear terminal is accepted or
ignored.
ON:
Enabled.
OFF:
Disabled.
5. Move the cursor to ALARM OUTPUT. Select an output
duration with the [–] or [+] button. The default setting is
10S (seconds).
The output status is supplied to the terminals on the
rear. The output is reset along with the activated alarm
according to this setup.
EXT:
The output is reset when a reset input is supplied
to the rear panel or the alarm reset button is
pressed on the front panel.
1S-5MIN:
The output is reset when the preset duration
elapses.
OFF:
No output.
6. Move the cursor to ALARM DATA. Select an output time
with the [–] or [+] button. The default setting is AUTO2.
The unit notifies the connected System Controller (must
be set to Unit #1) of the alarm activation once every
period preset by this setup.
POLLING:
The unit issues a notification only when the
controller inquires.
AUTO 1:
Notification is made immediately.
AUTO 2:
Notification is made once every 5 seconds.
7. Press ESC to return to the SYSTEM menu.
8
Cable compensation/VD2 sync/data setup
The COMP/VD2/DATA menu is displayed when you select it
in the SYSTEM menu.
In this menu, each camera is set up for cable compensa-
tion, VD2 sync and data communication ON/OFF.
1. Move the cursor to CAMERA IN. Select a camera input
channel with the [–] or [+] button. The default setting is
1CH.
The camera channel to be set up is selected and the
image of the channel is displayed in the background of
the setup menu.
Available channels:
1CH, 2CH, 3CH, 4CH
ALARM MODE
MONITOR SPOT ON
ALARM DISPLAY ON
SITE ALARM ON
TERM.ALARM ON
ALARM OUTPUT 10S
ALARM DATA AUTO2
SYSTEM
ALARM MODE ON
COMP/VD2/DATA
VS/VD INPUT VD
DAISY MODE ON
TERMINAL ALARM
COMP/VD2/DATA
CAMERA IN 1CH
COMP S
VD2 ON
DATA ON