![Panasonic WJMP204C - DATA MULTIPLEX UNIT Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/panasonic/wjmp204c-data-multiplex-unit/wjmp204c-data-multiplex-unit_operating-instructions-manual_278076025.webp)
25
8
CAM ADDRESS
Camera addresses are assigned to each of the unit's cam-
era input.
1. Move the cursor to CAM ADDRESS
, then press
SET. The CAM ADDRESS window appears.
2. Specify a number with the [–] or [+] button. The default
setting is 1.
Available numbers:
1-99, – (no assignment)
Note:
This setting takes effect only when the UNIT
switch is set to 0 on the front panel.
3. Repeat the above step until all camera inputs are given
addresses.
4. Press ESC to return to the communication setup.
8
BAUD RATE
1. Move the cursor to BAUD RATE, then specify a rate
with the [–] or [+] button. The default setting is 19 200.
Available rates (bit per second):
19 200, 9 600,
4 800, 2 400
8
DATA BIT
1. Move the cursor to DATA BIT, then specify a bit length
with the [–] or [+] button. The default setting is 8.
Available bit length:
7, 8
8
PARITY
1. Move the cursor to PARITY, then specify a check mode
with the [–] or [+] button. The default setting is NONE.
Available check modes:
NONE, EVEN, ODD
8
STOP BIT
1. Move the cursor to STOP BIT, then specify a bit length
with the [–] or [+] button. The default setting is 1.
Available bit length:
1, 2
8
WAIT TIME
The unit will retransmit data when there is no response dur-
ing the specified wait time.
1. Move the cursor to WAIT TIME, then specify a time with
the [–] or [+] button. The default setting is OFF.
Available wait times (ms):
OFF, 100, 200, 400,
1 000
8
DELAY TIME
This setting specifies a delay time that the unit suspends to
return the response to the received command.
1. Move the cursor to DELAY TIME, then specify a time
with the [–] or [+] button. The default setting is OFF.
Available delay times (ms):
OFF, 10, 20, 40, 100
8
X-ON/X-OFF
1. Move the cursor to XON/XOFF, then specify a mode
with [–] or [+] button. The default setting is NOT USE.
USE:
Data flow control is enabled during communica-
tion.
NOT USE:
Disabled.
2. Press ESC to return to the WJ-MP204C SETUP MENU.
●
System setup
(Camera Communication Protocol)
Parameters related to alarm, sync and remote functions are
set in this menu for a Camera Communication Protocol sys-
tem.
The SYSTEM menu is displayed when you select it in the
WJ-MP204C SETUP MENU.
8
Alarm mode setup
In the SYSTEM menu, move the cursor to ALARM MODE.
Select ON
or OFF with the [–] or [+] button, then press
SET. The default setting is ON
.
ON :
Opens a submenu shown below.
OFF:
Alarm mode is disabled.
CAM ADDRESS
CAMERA IN ADDRESS
1CH 1
2CH 2
3CH 3
4CH 4
SYSTEM
ALARM MODE ON
COMP/VD2/DATA
VS/VD INPUT VD
DAISY MODE ON
TERMINAL ALARM