Troubleshooting

Phenomenon

Cause

What to do

No power is supplied.

Power cord connection is insufficient.

Securely plug the cord into AC outlet and  AC
inlet..

HDD access lamps blink.

The Inner connector is loosening.

Securely  plug the inner connector.

Thermal error. OPERATE indicator
lights in orange.

Extension HDDs are not recog-
nized.

Ventilation openings or fan is blocked.

Cooling fan failed.

Remove obstacles.

Consult your dealer for the replacement.

SCSI ID setting

Set ID number properly.

Termination

Set termination properly.

SCSI cable

Use the supplied cable & connect it securely.

Power-on sequence

Turn on peripherals first, then HD500!

HDD unit position

Install HDD unit to the right position.

Ambient temperature is too low.

Use the unit 5 °C to +45 °C.

Specifications

Required Power:

220 V - 240 V 50 Hz

Power Consumption:

55 W (inclusive of 4 HDD units if installed)

Interface: 

SCSI-2 (FAST SCSI)  Half-pitch 50/pin D-Sub

Operating Temperature:

+5 °C to +45 °C (41 °F to 113 °F)

Dimensions:

420 mm (W) x 88 mm (H) x 350 mm (D), rubber feet exclusive
16-9/16” x 3-7/16” x 13-13/16”

Weight:

WJ-HDE500: 7.3 k

g

(16 lbs)

WJ-HDE505: 8.0 k

g

(17.6 lbs)

Weight and dimensions indicated are approximate.
Specifications are subject to change without notice.

Accessories

Power Cord  ...................................................................... 2 pcs.
SCSI Cable ....................................................................... 1 pc.
Rack Mounting Bracket..................................................... 2 pcs.
Bracket Fixing Screw ........................................................ 4 pcs.

NM1000-0

V8QA5622AN

Printed in Japan

N

19

2000

© Matsushita Communication Industrial Co., Ltd.  All rights reserved.

Matsushita Electric Industrial Co., Ltd.

Central P.O. Box 288, Osaka 530-91, Japan

Содержание WJHD500 - DIGITAL DISC RECORDE

Страница 1: ...or the BSI mark G on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be use...

Страница 2: ...aarop deze verklaring betrekking heeft voldoet aan de volgende normen of andere normatieve documenten overeenkomstig de bepalingen van Richtlijnen 73 23 EEC en 89 336 EEC Vi erkl rer os eneansvarlige...

Страница 3: ...GE TO ORANGE IF THE INSEDE TEMPERATURE EXCEEDS OR FALLS BELOW THE LIMIT Front View u Termination Switch TERMINATE ON OFF Set this switch to ON when the extension unit is located at the end of SCSI cha...

Страница 4: ...d to the right and remove it 2 Remove the HDD bracket 1 2 1 Loosen 2 screws as shown 2 2 Pull the bracket 1 out of the opening 3 Disassemble the bracket 1 Separate it into the fixing bracket and dummy...

Страница 5: ...connector on the HDD as shown Note For further details refer to the instructions included in the HDD unit 7 Place the HDD into the appropriate opening then fix it with 2 screws 8 Plug the 2 connector...

Страница 6: ...NC OFF OFF ON ON ON ON OFF OFF SIGNAL GND SIGNAL GND PO POWER WER AC IN C IN SCSI ID SCSI ID EXT OUT EXT OUT EXT IN EXT IN TERMINA TERMINATOR OR GND GND THERMAL ERR THERMAL ERROR OUT OR OUT NC NC OFF...

Страница 7: ...m overheating 1 SCSI ID TERMINATION ON OFF 1234 MODE ON Remove 4 screws M3X10 Supplied Rack Mounting Bracket Supplied M5X12 Not supplied Switch Settings 1 Set the MODE switch 2 on the rear of the WJ H...

Страница 8: ...Install HDD unit to the right position Ambient temperature is too low Use the unit within 5 C to 45 C Specifications Required Power 220 V 240 V 50 Hz Power Consumption 55 W inclusive of 4 HDD units i...

Отзывы: