Set up terminal alarm [Advanced terminal alarm setup]
Configure the settings relating to the recording triggered by an alarm signal supplied to the ALARM/CONTROL
connector of the recorder from an external alarm device such as a door sensor.
Configure the necessary settings for each alarm input terminal of the ALARM/CONTROL connector on the rear
panel of the recorder.
■
Advanced terminal alarm setup
[Mode]
Select the action to be taken when an alarm signal is
supplied.
Recording & alarm action: Performs all event
actions according to the settings.
Recording only: Only recording, filing of event
logs, and moving the camera to a preset posi-
tion will be performed.
Off: Only filing of event logs will be performed.
Default:
Recording & alarm action
[Alarm logs]
Determine whether or not to save the alarm logs.
Save: Logs will be saved.
Not save: Logs will not be saved.
Default:
Save
[Setup by terminal]
Set up individual terminals numbered from 1 to 9.
[Recording camera]
Select the camera for recording. When "Off" is
selected, recording will not be performed.
All: Applies all the registered cameras for record-
ing.
Default:
Camera number associated with the terminal
number
Note:
When many cameras are registered and "All" is
•
selected for "Recording camera", the start of
alarm recording may be delayed depending on the
cameras. It is recommended to perform pre-event
recording.
[Preset]
Select the camera preset position (001 to 256) to
which the camera is to be moved when an alarm sig-
nal is received. If "---" is selected, the camera will not
be moved to a preset position.
[Terminal output]
Choose whether or not to output an alarm signal from
the alarm output terminal of the ALARM/CONTROL
connector on the recorder’s rear panel when an alarm
signal is received.
On: Outputs alarm signals.
Off: Does not output alarm signals.
Default:
On
[Terminal input]
Select the terminal status for supplying an alarm sig-
nal to the alarm terminal.
N.O. (Normally Open): Signals will be supplied
when short-circuited.
N.C. (Normally Close): Signals will be supplied
when open-circuited.
Default:
N.O.