background image

4

CONTROL PANEL

•  Some functions described in this manual may not be applicable to your unit.
•  Consult your nearest authorized dealer for further information.

•  For normal operation, the 

ERROR

RESET

 , 

FORCE

 and 

PUMPDW

 buttons are not in use.

1

OFF/ON Button

14

Quiet Operation OFF/ON Indicator

2

Operation LED

15

Backup Heater Enabled/Disabled Indicator

3

Operation Mode Button

16

Force Heater Request OFF/ON Indicator

4

Quiet Operation Button

17

Backup Heater Actual Operation (OFF/ON) Indicator

5

Indoor Unit Backup Heater Enabling Button

18

Booster Heater Actual Operation (OFF/ON) Indicator

6

System Setting Mode Buttons

19

System Setting Mode OFF/ON Indicator

7

Timer Setting Group Buttons

20

System Status Check Mode OFF/ON Indicator

8

Force Heater Mode Button

21

System Pumpdown Mode OFF/ON Indicator

9

System Pumpdown Mode Button

22

Timer/Clock Setting Display

10

System Status Check Mode Buttons

23

External Thermo Controller Connected Display

11

Heat Mode OFF/ON Indicator

24

Outdoor Ambient Temperature Display

12

Cool Mode OFF/ON Indicator

25

Water Outlet Temperature Display

13

Tank Mode OFF/ON Indicator

26

Solar Display

27

Error Reset Button

Notes:

•  The current day and time need to be set when: 

-  The power is turned on for the 

fi

 rst time.

-  After a long time has elapsed since the power was last 

turned on.

•  The current time that has been set will be the standard 

time for all the Timer operations. 

1. Press 

CLOCK

.

2. Press 

 or 

 to set current day.

3. Press 

SET

 to con

fi

 rm.

4. Repeat steps 2 and 3 to set the current time.

CONTROL PANEL PREPARATION

Setting Current Day and Time

TIMER

OUTDOOR

HEAT

SETTING
STATUS
PUMPDW

BOOSTER

QUIET

TANK

WATER OUTLET

C

C

SET

SELECT

CANCEL

ERROR

RESET

SETTING

STATUS

SEARCH

PUMPDW

FORCE

CLOCK

CHECK

OFF /ON

MODE

HEATER

QUIET

OFF/ON

TIMER

HEATER 

OPERATION

FORCE

HEATER 

ACTUAL

TIMER

1

MONTUEWEDTHU FRI SAT SUN

SOLAR REMOTE

2 3 4 5 6

ON
OFF

COOL

16

1

22

21

10

17
18
19
20

24

9

5

25

3

8

4

7

2

15

14

13

6

27

23

26

12 11

Содержание WH-UX12DE8

Страница 1: ... di utilizzare l unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro Prima di far funzionare l unità assicurarsi che l installazione sia stata eseguita correttamente da un rivenditore autorizzato e seguendo precisamente le istruzioni date per l installazione 42 51 42 51 NEDERLANDS Lees voor u het apparaat gebruikt deze gebruik...

Страница 2: ...back in the limits To prevent personal injury injury to others or property damage please comply with the following Incorrect operation due to failure to follow instructions below may cause harm or damage the seriousness of which is classified as below WARNING WARNING This sign warns of death or serious injury CAUTION CAUTION This sign warns of injury or damage to property The instructions to be fo...

Страница 3: ...e or electric shock Do not share the same power outlet with other equipment Do not operate with wet hands Do not over bend the power supply cord If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This unit is equipped with Residue Current Circuit Breaker RCCB It is strongly recommended to check the operat...

Страница 4: ...m Status Check Mode Buttons 23 External Thermo Controller Connected Display 11 Heat Mode OFF ON Indicator 24 Outdoor Ambient Temperature Display 12 Cool Mode OFF ON Indicator 25 Water Outlet Temperature Display 13 Tank Mode OFF ON Indicator 26 Solar Display 27 Error Reset Button Notes The current day and time need to be set when The power is turned on for the first time After a long time has elaps...

Страница 5: ... SET to confirm Function Operation Mode Actual Operation Description External Thermo Controller YES NO To set external thermo controller connection TANK Tank Connection YES NO To set tank connection SOLAR Solar Priority YES NO To choose the solar use for water tank heat up HEAT Heating Priority YES NO To choose the heat pump only use for Heating side during HEAT TANK mode HEAT Heating Heat up Inte...

Страница 6: ...oor unit COOL TANK MODE In this mode the outdoor unit will provide cooling capacity to the indoor unit Indoor unit will control booster heater in sanitary tank QUIET TO ENJOY QUIET ENVIRONMENT This operation reduces outdoor unit noise In this condition it may cause decrease in heating cooling capacity HEATER TO ENABLE THE BACKUP HEATER The backup heater provides extra heating capacity during cold ...

Страница 7: ...other parameters Operation Mode Parameter Description HEAT Low outdoor ambient set temperature 15 C 15 C HEAT High outdoor ambient set temperature 15 C 15 C HEAT Water outlet set temperature at low outdoor ambient temperature 25 C 55 C HEAT Water outlet set temperature at high outdoor ambient temperature 25 C 55 C HEAT OFF Set temperature for turning OFF heating operation 5 C 35 C HEATER ON Outdoo...

Страница 8: ...eps 4 to 7 to set programs 2 to 6 During timer setup if no button is pressed within 30 seconds or if the SET button is pressed the setting at that moment is confirmed and timer setup is ended Add Modify timer Repeat the steps above Disable timer Press TIMER then press CANCEL Enable timer Press TIMER then press SET Check timer 1 Press TIMER 2 Press or until your desired day is shown press SELECT to...

Страница 9: ...e the unit gently with a soft dry cloth EXTERNAL FILTER Please clean the external filter at least once a year Fail to do so might cause filter clogged consequent system breakdown Please consult authorized dealer OUTDOOR UNIT Do not obstruct the air inlet and air outlet vents it may cause low performance or breakdown Please remove obstacles to assure the ventilation During winter please clean and r...

Страница 10: ...rm System cannot get warm instantly Due to the nature of the heatpump system it may take some time to heat up the water if the unit is operated from cold start Operation starts after power resumes Unit is operates under auto restart function Check the following before calling for servicing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Heating cooling operation is not...

Страница 11: ...n health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products please contact your local municipality your waste disposal service or the point of sale where you purchased the items Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users...

Страница 12: ...Panasonic Corporation Website http panasonic net Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Service Europe a division of Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany ...

Отзывы: