3. Features
Inverter Technology
- Energy saving
High Efficiency
Compact Design
Environment Protection
- Non-ozone depletion substances refrigerant (R410A)
Long Installation Piping
- Long piping up to 15 meter with height difference 5 meter
- Flexible 4-way piping for outdoor unit
Easy to use control panel
Weekly Timer setting
Quality Improvement
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
Serviceability Improvement
- Breakdown Self Diagnosis function
- System Status Check Buttons for servicing purpose
- System Pumpdown Button for servicing purpose
- Front maintenance design for outdoor unit
Operation Condition
Indoor
Outdoor
Water outlet temperature (°C)
Ambient temperature (°C)
COOLING
Maximum
20
43
Minimum
5
16
HEATING
Maximum
55
35
Minimum
20
-20
NOTICE : When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly
and outdoor unit might stop for protection control.