Default Setting
Setting Options / Display
6 Installer
setup Operation setup
To access to the four major
functions or modes.
4 main modes
Heat / *
1,
*
2
Cool / *
1,
*
2
Auto / *
3
Tank
6.1
Heat
To set various water & ambient
temperatures for heating.
Water temp. for heating ON /
Outdoor temp. for heating OFF /
T for heating ON /
Heater ON/OFF
Water temp. for heating ON
Compensation curve
Heating ON
temperatures in
compensation curve
or direct input.
Water temp. for heating ON Compensation curve
X axis: -5 °C, 15 °C
Y axis: 55 °C, 35 °C
Input the 4
temperature points
(2 on horizontal X
axis, 2 on vertical Y
axis).
Heat ON: Water temp.:Zone1
Confirm
Select
55°C
75
20
-20
15
35°C
-5°C
15°C
•
Temperature range: X axis: -20 °C ~ 15 °C, Y axis: See below
•
Temperature range for the Y axis input:
WH-WDG model: 20 °C ~ 75 °C
Regardless of the above setting, there is a limit to the water temperature. Refer to
the operating condition on page 3.
•
If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
•
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for heating ON Direct
35 °C
Temperature for
heating ON
Operation setup
Heat ON: Water temp.:Zone2
Range: (20°C~75°C)
Steps: ±1°C
Select
Confirm
10:34am,Mon
35
°C
•
Min. ~ Max. range is 20 °C ~ 75 °C:
WH-WDG model: 20 °C ~ 75 °C
Regardless of the above setting, there is a limit to the water temperature. Refer to
the operating condition on page 3.
•
If 2 zone system is selected, temperature set point must input for Zone 2.
•
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available).
*
3
Only displayed when Tank connection is Yes.