32
Menus
For installer
Menu
Default Setting
Setting Options / Display
5 Installer
setup System setup
5.1
Optional PCB connectivity
To connect to the external PCB
required for servicing.
No
•
If the external PCB is connected (optional), the system will have following additional functions:
1
Control over 2 zones (including the swimming pool and the function to heat water in it).
2
Solar function (the solar thermal panels connected to either the DHW (Domestic Hot Water) Tank or the Buffer Tank.
•
DHW is not applicable for WH-ADC models.
3
External compressor switch.
4
External error signal.
5
SG ready control.
6
Demand control.
7
Heat-Cool SW
5.2
Zone & Sensor
To select the sensors and to
select either 1 zone or 2 zone
system.
Zone
•
After selecting 1 or 2 zone system, proceed
to the selection of room or swimming pool.
•
If the swimming pool is selected, the
temperature must be selected for
T temperature between 0°C ~ 10 °C.
Sensor
For room thermostat, there is a further
selection of external or internal.
•
If select internal, there is a further selection
of RC-1 or RC-2 (only available when Zone
selection is 1 zone system).
Select RC-1 if main remote controller’s
thermistor is to be used for room temperature
control and vice versa.
5.3
Heater capacity
To reduce the heater power if
unnecessary.*
3 kW / 6 kW / 9 kW
* Options of kW vary depending
on the model.
5.4
Anti freezing
To activate or deactivate the
water freeze prevention when
the system is OFF
Yes
5.5
Tank connection
To connect tank to the system.
No