background image

CAUTION 

WARNING 

WARNING

1. Safety Precautions 

  Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. 

  Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating and main 

circuit for the model installed. 

  The caution items stated here must be followed because these important contents are related to safety. The 

meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction 
will cause harm or damage, and the seriousness is classified by the following indications. 

 

 

This indication shows the possibility of causing death or serious injury. 

 

This indication shows the possibility of causing injury or damage to properties. 

 

  The items to be followed are classified by the symbols: 

 

 

  Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation, 

care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for 
future reference. 

 

 

1.   Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other
      electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 

 

2.   Do not install outdoor unit near handrail of veranda. When installing outdoor unit at veranda of high rise building, child may climb up to
      outdoor unit and cross over the handrail and causing accident. 

 

3.   Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen. 

 

4.   Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.   

 (For Outdoor Unit) 

 

5.   Do not sit or step on the unit, you may fall down accidentally.   

 (For Outdoor Unit) 

 

6.   Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing. 

 

7.   Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction. 

 

8.   Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fire. 

 

9.   Do not modify the wiring of outdoor unit for installation of other components (i.e. heater, etc.). Overloaded wiring or wire connection 
      points may cause electrical shock or fire. (For Outdoor Unit) 

 

10. Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc. 

 

11. Do not use the hot water produced by the Tank Unit for drinking or food preparation. It may cause illness to the user. 

 

12. Do not place containers with liquids on top of the Tank Unit. It may cause Tank Unit damage and/or fire could occurs if they leak or 
      spill onto the Tank Unit. 

 

13. For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be
      used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire. 
14. For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building
      regulation codes. (For Tank Unit) 
15. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 
16. • This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause
         abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A refrigerant. 
       • Thickness or copper pipes used with R410A must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm. 

         • It is desirable that the amount of residual oil is less than 40 mg/10 m. 

17. When install or relocate Tank Unit / Outdoor Unit, do not let any substance other than the specified refrigerant, eg. air etc. mix into refrigerant
      cycle (piping). Mixing of air etc. will cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc. 
18. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire. 
19. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
      done, the set will drop and cause injury. 
20. Do not use joint cable for Tank Unit / Outdoor Unit connection cable. Use specified Tank Unit / Outdoor Unit connection cable, refer to
       instruction 

CONNECT THE CABLE TO THE TANK UNIT / CONNECT THE CABLE TO THE OUTDOOR UNIT 

and connect tightly for

       Tank Unit / Outdoor Unit connection. Clamp the cable so that no external force will be acted on the

 

terminal. If connection or fixing is not

       perfect, it will cause heat up or fire at the connection. 
21. This equipment is strongly recommended to be installed with Residual Current Device (RCD) on-site according to the respective national
       wiring rules or country–specific safety measures in terms of residual current. (For Tank Unit) 
22. During installation, install the refrigerant piping properly before run the compressor. Operation of compressor without fixing refrigeration
       piping and valves at opened condition will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury
       etc. 
23. During pump down operation, stop the compressor before remove the refrigeration piping. Removal of refrigerant piping while compressor is
      operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigerant cycle and result in explosion, injury etc. 

 

This symbol denotes item that is PROHIBITED from doing. 

Содержание WH-ADC1216G6E5

Страница 1: ...s not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the products dealt with in this service information by anyone else could result in serious injury or death PRECAUTION OF LOW TEMPERA...

Страница 2: ...o the Tank Unit 13 For electrical work follow local wiring standard regulation and this installation instruction An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock or fire 14 For water circuit installation work follow to relevant European and national regulations including EN61770 and ...

Страница 3: ...thed The electrical earth must not be connected to a gas pipe water pipe the earth of lightning rod or a telephone Otherwise there is a danger of electrical shock in the event of an insulation breakdown or electrical earth fault in the Tank Unit Outdoor Unit 1 Do not install the Tank Unit Outdoor Unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surroundin...

Страница 4: ...e Refrigeration Oil cm 3 FV50S 1200 Refrigerant R410A kg oz 2 85 100 6 Dimension Height mm inch 1340 52 3 4 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 101 223 Pipe Diameter Liquid mm inch 9 52 3 8 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 50 0 5 Refrigerat...

Страница 5: ...or Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 25 55 Internal Pressure Differential kPa Cooling 20 0 Heating 31 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 33 Heating 33 Power Level dB Cooling 46 Heating 46 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth mm inch 1800 70 27 32 Net We...

Страница 6: ...85 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Anode Material Aluminium Diameter mm 20 Length mm 1000 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heating capacities are based on out...

Страница 7: ...ation Oil cm 3 FV50S 1200 Refrigerant R410A kg oz 2 85k 100 6 Dimension Height mm inch 1340 52 3 4 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 101 223 Pipe Diameter Liquid mm inch 9 52 3 8 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 50 0 5 Refrigeration Charg...

Страница 8: ...N 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 25 55 Internal Pressure Differential kPa Cooling 38 0 Heating 52 5 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 33 Cooling 33 Power Level dB Cooling 46 Cooling 46 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth...

Страница 9: ...Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Anode Material Aluminium Diameter mm 20 Length mm 1000 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heatin...

Страница 10: ...ration Oil cm 3 FV50S 1200 Refrigerant R410A kg oz 2 55 90 0 Dimension Height mm inch 1340 52 3 4 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 101 223 Pipe Diameter Liquid mm inch 9 52 3 8 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 50 0 5 Refrigeration Charge...

Страница 11: ...N 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 25 55 Internal Pressure Differential kPa Cooling 38 0 Heating 52 5 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 33 Cooling 33 Power Level dB Cooling 46 Cooling 46 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth...

Страница 12: ...Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Anode Material Aluminium Diameter mm 20 Length mm 1000 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heatin...

Страница 13: ...eration Oil cm 3 FV50S 1200 Refrigerant R410A kg oz 2 55 90 0 Dimension Height mm inch 1340 52 3 4 Width mm inch 900 35 7 16 Depth mm inch 320 12 19 32 Net Weight kg lbs 150 331 Pipe Diameter Liquid mm inch 9 52 3 8 Gas mm inch 15 88 5 8 Standard Length m ft 5 16 4 Pipe Length Range m ft 3 9 8 30 98 4 I D O D Height Difference m ft 20 65 6 Additional Gas Amount g m oz ft 50 0 5 Refrigeration Charg...

Страница 14: ...N 14511 Operation Range Outdoor Ambient C min max Cooling 16 43 Heating 20 35 Water Outlet C min max Cooling 5 20 Heating Tank 65 Heating Circuit 25 55 Internal Pressure Differential kPa Cooling 54 5 Heating 94 0 Noise Level Condition Ambient Water A35W7 A7W35 A2W35 dB A Cooling 33 Cooling 33 Power Level dB Cooling 46 Cooling 46 Dimension Height mm inch 717 28 7 32 Width mm inch 598 23 17 32 Depth...

Страница 15: ...Material En 1 4521 Volume L 185 Design Pressure Bar 10 Heat Exchanger Material EN 1 4162 EN 1 4521 Diameter mm 22 Thickness mm 0 8 Surface Area m 2 1 8 Total Length m 25 Anode Material Aluminium Diameter mm 20 Length mm 1000 Note Cooling capacities are based on outdoor air temperature of 35 C Dry Bulb with controlled indoor water inlet temperature of 12 C and water outlet temperature of 7 C Heatin...

Страница 16: ... function o Weekly timer setting A class energy efficiency pump o Water pump speed can be set by selection at control panel Improved deice cycle Protection Feature o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor Serviceability Feature o Breakdown Self Diagnosis function o Syst...

Страница 17: ...sure Relief Valve e Flow Switch f h g Water Pressure Gauge Top Front Plate Bottom Front Plate i Top Plate j Right Plate k Left Plate l Rear Plate m Tank Sensor Not Visible Connector name Water Inlet From Space Heating Cooling a Water Outlet To Space Heating Cooling b Cold Water Inlet Domestic Hot Water Tank c Hot Water Outlet Domestic Hot Water Tank d Refrigerant Gas e Refrigerant Liquid f Domesti...

Страница 18: ...27 4 2 Outdoor Unit Air inlet rear Air inlet side Air inlet side Air outlet Air outlet ...

Страница 19: ...28 5 Dimensions 5 1 Indoor Unit Top View Bottom View Front View Side View Unit mm 1800 598 60 70 36 612 60 478 156 427 29 562 717 319 1329 295 ...

Страница 20: ...29 5 2 Outdoor Unit Top View Space necessary for installation Anchor Bolt Pitch 355 x 260 100 cm 10 cm Front View Side View Unit mm Side View 40 1340 320 900 620 140 140 355 400 320 40 20 10 cm ...

Страница 21: ...OR 3 WAY VALVE ANODE BAR AIR TEMP SENSOR HEAT EXCHANGER HEAT EXCHANGER WATER TANK WATER DISCHARGE VALVE FLOOR HEATING WATER OUTLET FLOOR HEATING WATER INLET SANITARY HOT WATER OUTLET SANITARY COLD WATER INLET STRAINER STRAINER COMPRESSOR 4 WAY VALVE TANK TEMP SENSOR DISCHARGE TEMP SENSOR HIGH PRESSURE SWITCH DISCHARGE MUFFLER MUFFLER EXPANSION VALVE OUTDOOR UNIT INDOOR UNIT PRESSURE RELIEF VALVE F...

Страница 22: ... BL DATA RED G04 GRN G03 GRN RY HT L3 RY HT L2 HT1 L3 RED HT1 L2 ORG AC2 L2 YLW AC2 N2 WHT AC2 L3 BLK SURGE PROTECTION CIRCUIT SIGNAL DETECTION CIRCUIT SIGNAL DETECTION CIRCUIT 80 3 C CN OLP1 WHT 2 B B TERMINAL BOARD TERMINAL BOARD BACKUP HEATER 3kW x 2 R 0 Y OLP 80 3 C OLP 80 3 C BL R BL BL BL W O O 1 1 2 2 L 1 N 1 W W W GROUNDING ELCB T3 G G 1 1 3 3 2 2 A B R B R O BL Y CONTROL PANEL G01 GRN REC...

Страница 23: ...ED R 1 AC WHT02 1 T3 15A L250V WHITE COMMUNICATION RY HT2 6 AC L CIRCUIT CN HT2 RY HT1 CN HOT M 1 CN HT1 RED 1 BL 4 CN HPS RECTIFICATION FILTER W G CN WHT WHITE RED DCP CN EV 6 2 CN RY1 SWITCHING POWER SUPPLY CIRCUIT RECTIFICATION CIRCUIT PFC CIRCUIT DCN IN CIRCUIT AC C BLUE DCN BLACK 2 DCN2 BLACK FUSE1 1 CN FM2 WHITE 1 4 7 7 4 2 CN FM1 CN PSW1 CN EV2 LOWER FAN MOTOR BLACK V U U RED P N V BLUE RED...

Страница 24: ... HITE COMMUNICATION RY HT2 A C L CIRCUIT CN HT2 RY HT1 CN HO T M 1 CN HT1 RE D 1 BL 4 3 CN HP S RECTIFICATION W G CN W HT W HITE RE D DC P CN E V 6 2 CN RY 1 SWITCHINGPOWER SUPPLYCIRCUIT RECTIFICATION CIRCUIT PFC CIRCUIT DCN IN A C C B LUE DC N B LA CK 2 DCN 2 B LA CK F U SE 1 CN FM 2 W HITE 1 4 7 7 4 2 CN FM 1 CN PS W 1 LOW E R FA N M O TOR B LA CK V U U RE D P N V B LUE RE D TO B LUE B LA CK 3 2...

Страница 25: ...min The available external static pressure kPa in function of the water flow rate L min is shown in the P Q graph Depend on the hydraulic system pressure loss and type the water flow rate can be adjusted by Control Panel 1 When the Tank Unit is in stop operation press SERVICE button for 5 seconds 2 Press button to select menu S02 PUMP SPEED ADJUST MODE and press SET button to confirm the menu 3 Pr...

Страница 26: ...tdoor air temperature 7 C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 1 000 2 000 3 000 4 000 5 000 6 000 15 11 7 3 1 5 9 13 17 21 25 8 000 9 000 10 000 11 000 12 000 13 000 14 000 15 11 7 3 1 5 9 13 17 21 25 ...

Страница 27: ... DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 5 000 6 000 7 000 8 000 9 000 10 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 28: ...DBT C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 7 000 8 000 9 000 10 000 11 000 12 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 29: ...or water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 18 21 24 27 30 33 36 39 42 45 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 5 000 6 000 7 000 8 000 9 000 10 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 30: ... C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 0 500 1 000 1 500 2 000 2 500 3 000 3 6 9 12 15 18 21 24 27 30 5 000 6 000 7 000 8 000 9 000 10 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 31: ... 35 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 2 000 2 100 2 200 2 300 2 400 2 500 3 6 9 12 15 18 21 24 27 30 4 000 5 000 6 000 7 000 8 000 9 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 32: ...7 C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Outdoor Temperature C Input Power kW Outdoor Temperature C Capacity kW 1 000 2 000 3 000 4 000 5 000 6 000 15 11 7 3 1 5 9 13 17 21 25 10 000 11 000 12 000 13 000 14 000 15 000 15 11 7 3 1 5 9 13 17 21 25 ...

Страница 33: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 7 000 8 000 9 000 10 000 11 000 12 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 34: ...BT C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 8 000 10 000 12 000 14 000 16 000 18 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 35: ...DBT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 18 21 24 27 30 33 36 39 42 45 5 000 7 000 9 000 11 000 13 000 15 000 18 21 24 27 30 33 36 39 42 45 ...

Страница 36: ...C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Piping Length m Input Power kW Piping Length m Capacity kW 8 000 9 000 10 000 11 000 12 000 13 000 3 6 9 12 15 18 21 24 27 30 1 500 2 000 2 500 3 000 3 500 4 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 37: ...35 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 3 300 3 400 3 500 3 600 3 700 3 800 3 6 9 12 15 18 21 24 27 30 6 000 7 000 8 000 9 000 10 000 11 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 38: ...temperature 7 C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 1 000 2 000 3 000 4 000 5 000 6 000 15 11 7 3 1 5 9 13 17 21 25 8 000 9 000 10 000 11 000 12 000 13 000 15 11 7 3 1 5 9 13 17 21 25 ...

Страница 39: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 16 19 22 25 28 31 34 37 40 43 7 500 8 500 9 500 10 500 11 500 12 500 16 19 22 25 28 31 34 37 40 43 ...

Страница 40: ...T C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 16 19 22 25 28 31 34 37 40 43 11 000 12 000 13 000 14 000 15 000 16 000 16 19 22 25 28 31 34 37 40 43 ...

Страница 41: ...DBT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 16 19 22 25 28 31 34 37 40 43 7 000 8 000 9 000 10 000 11 000 12 000 16 19 22 25 28 31 34 37 40 43 ...

Страница 42: ... DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 1 500 2 000 2 500 3 000 3 500 4 000 3 6 9 12 15 18 21 24 27 30 10 000 10 500 11 000 11 500 12 000 12 500 3 6 9 12 15 18 21 24 27 30 ...

Страница 43: ...35 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 3 300 3 400 3 500 3 600 3 700 3 800 3 6 9 12 15 18 21 24 27 30 6 000 7 000 8 000 9 000 10 000 11 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 44: ...emperature 7 C DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 1 000 2 000 3 000 4 000 5 000 6 000 15 11 7 3 1 5 9 13 17 21 25 10 000 11 500 13 000 14 500 16 000 17 500 15 11 7 3 1 5 9 13 17 21 25 ...

Страница 45: ...DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 16 19 22 25 28 31 34 37 40 43 6 000 8 000 10 000 12 000 14 000 16 000 16 19 22 25 28 31 34 37 40 43 ...

Страница 46: ...T C WBT Indoor water inlet temperature 19 C Indoor water outlet temperature 14 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 1 500 2 500 3 500 4 500 5 500 6 500 16 19 22 25 28 31 34 37 40 43 12 000 14 000 16 000 18 000 20 000 22 000 16 19 22 25 28 31 34 37 40 43 ...

Страница 47: ...BT C WBT Indoor water inlet temperature 23 C Indoor water outlet temperature 18 C Piping length 7 m Outdoor Temperature C Capacity kW Outdoor Temperature C Input Power kW 0 500 1 500 2 500 3 500 4 500 5 500 16 19 22 25 28 31 34 37 40 43 7 000 9 000 11 000 13 000 15 000 17 000 16 19 22 25 28 31 34 37 40 43 ...

Страница 48: ... DBT 6 C WBT Indoor water inlet temperature 30 C Indoor water outlet temperature 35 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 3 200 3 400 3 600 3 800 4 000 4 200 3 6 9 12 15 18 21 24 27 30 14 500 15 000 15 500 16 000 16 500 17 000 3 6 9 12 15 18 21 24 27 30 ...

Страница 49: ...5 C DBT C WBT Indoor water inlet temperature 12 C Indoor water outlet temperature 7 C Piping length 7 m Piping Length m Capacity kW Piping Length m Input Power kW 4 500 4 600 4 700 4 800 4 900 5 000 3 6 9 12 15 18 21 24 27 30 8 500 9 500 10 500 11 500 12 500 13 500 3 6 9 12 15 18 21 24 27 30 ...

Страница 50: ... 12000 2960 12000 3390 12000 3780 12000 4160 25 13600 1550 13600 1760 13400 2100 13200 2430 12600 2660 12000 2890 18 2 3 WH UD12FE5 Water Out C 30 35 40 45 50 55 Outdoor Air C Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W 15 9300 3460 8900 3620 8500 3790 8100 3950 7500 4050 7000 4160 7 10400 337...

Страница 51: ...00 1400 25 11200 2670 16500 3010 10000 1600 35 10000 3560 12550 3630 10000 1950 43 8000 3350 10000 3460 8000 2300 18 3 3 WH ADC1216G6E5 WH UD12FE5 Water In C 12 19 23 Water Out C 7 14 18 Outdoor Air C Capacity W Input Power W Capacity W Input Power W Capacity W Input Power W 16 7860 1180 13150 1400 10000 1730 25 12080 2900 15700 2050 10000 1970 35 10000 2560 12000 2670 10000 2400 43 7800 3800 1110...