17
Signal inputs
Optional
Thermostat
L N =AC230V, Heat, Cool=Thermostat heat, Cool terminal
External
control
Dry contact Open=not operate, Short=operate (System setup necessary)
Able to turn ON/OFF the operation by external switch
Remote
controller
Connected (Please use 2 cores wire for relocation and extension. Total
cable length shall be 50m or less.)
Outputs
3-way valve
AC230V N=Neutral Open, Close=direction (For
circuit switching when connected to DHW tank)
AC230V, 12 VA
2-way valve
AC230V N=Neutral Open, Close (Prevent water
circuit pass through during cooling mode)
AC230V, 12 VA
Extra pump
AC230V (Used when Tank Unit pump capacity is
insuffi cient)
AC 230V,
0.6 A max
Boiler contact /
Defrost signal
Dry contact (System setup necessary)
Thermistor inputs
Zone 1 room
sensor
PAW-A2W-TSRT
Outdoor air sensor PAW-A2W-TSOD (Total cable length shall be 30m or less)
Connection of Optional PCB (CZ-NS5P)
Ext.
comp.
SW
Heat/
Cool
SW
SG
signal
Bit1
Bit2
Vcc
Solar
sensor
Mixing
valve 2
Mixing
valve 1
Optional
Thermostat 2
Demand
signal
Zone 1
water
sensor
Zone 2
water
sensor
Pool
water
sensor
Zone 2
room
sensor
Zone 1
Pump
Error
signal
Pool
Pump
Solar
Pump
Zone 2
Pump
L
N Cool Heat
N
O
C
N
O
C
Signal inputs
Optional Thermostat
L N =AC230V, Heat, Cool=Thermostat heat, Cool terminal
SG signal
Dry contact Vcc-Bit1, Vcc-Bit2 open/short (System
setup necessary)
Switching SW (Please connect to the 2 contacts controller)
Heat/Cool SW
Dry contact Open=Heat, Short=Cool (System setup
necessary)
External comp.SW
Dry contact Open=Comp.OFF, Short=Comp.ON
(System setup necessary)
Demand signal
DC 0~10V (System setup necessary)
Please connect to the DC 0~10V controller.
Outputs
Mixing valve
AC230V N=Neutral Open,
Close=mixture
direction
Operating time: 30s~120s
AC230V, 6VA
Pool pump
AC230V
AC 230V, 0.6 A max
Solar pump
AC230V
AC 230V, 0.6 A max
Zone pump
AC230V
AC 230V, 0.6 A max
Thermistor inputs
Zone room sensor
PAW-A2W-TSRT
Buffer tank sensor
PAW-A2W-TSBU
Pool water sensor
PAW-A2W-TSHC
Zone water sensor PAW-A2W-TSHC
Solar sensor
PAW-A2W-TSSO
Recommended External Device Specifi cation
•
This section explains about the external devices (optional)
recommended by Panasonic. Please always ensure to use the
correct external device during system installation.
•
For optional sensor.
1. Buffer tank sensor: PAW-A2W-TSBU
Use for measurement of the buffer tank temperature.
Insert the sensor into the sensor pocket and paste it on the
buffer tank surface.
40
black
brown
blue
Dimensions (mm)
Ø6
2. Zone water sensor: PAW-A2W- TSHC
Use to detect the water temperature of the control zone.
Mount it on the water piping by using the stainless steel metal
strap and contact paste (both are included).
93
70
35
Dimensions (mm)
3. Outdoor sensor: PAW-A2W-TSOD
If the installation location of the outdoor unit is exposed to direct
sunlight, the outdoor air temperature sensor will be unable to
measure the actual outdoor ambient temperature correctly.
In this case, optional outdoor temperature sensor can be fi xed at a
suitable location to more accurately measure ambient temperature.
70
93
46
Dimensions (mm)
4. Room sensor: PAW-A2W- TSRT
Install the room temperature sensor to the room which requires
room temperature control.
Dimensions (mm)
86
86
60
30
5. Solar sensor: PAW-A2W-TSSO
Use for measurement of the solar panel temperature.
Insert the sensor into the sensor pocket and paste it on the solar
panel surface.
40
black
brown
blue
Dimensions (mm)
Ø6
6. Please refer to the table below for sensor characteristic of the
sensors mentioned above.
Temperature
(°C)
Resistance
(k
Ω
)
Temperature
(°C)
Resistance
(k
Ω
)
30
5.326
150
0.147
25
6.523
140
0.186
20
8.044
130
0.236
15
9.980
120
0.302
10
12.443
110
0.390
5
15.604
100
0.511
0
19.70
90
0.686
-5
25.05
80
0.932
-10
32.10
70
1.279
-15
41.45
65
1.504
-20
53.92
60
1.777
-25
70.53
55
2.106
-30
93.05
50
2.508
-35
124.24
45
3.003
-40
167.82
40
3.615
35
4.375