[Programmable Items]
Item
Description
Outgoing intercom call
Controls whether the outgoing intercom calls are recorded.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—Print Information—Intercom Call
Date order
The date order is changeable: month/day/year, day/month/year,
year/month/day, year/day/month.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—SMDR Format—Date Format
Time format
Controls whether time is displayed in 12-hour or 24-hour format.
→ 12.1 Control Box Configuration—[11-1] Maintenance—Main
—SMDR—SMDR Format—Time Format (12H / 24H)
Conditions
[General]
•
SMDR data is not deleted even if the Control Box is reset.
•
SMDR data from a user is not deleted even if the user is deleted.
If the user is deleted while some SMDR data has not been output, the SMDR data may be output as
SMDR data for a new user added later.
•
If the Control Box is reset during a conversation, the call will not be recorded on SMDR.
[Output to a Telnet compatible Terminal Emulator]
•
In order to activate a connection to a terminal emulator, the IP address of the mother board, port number,
user ID ("SMDR"), and password must be entered.
•
If a terminal emulator user incorrectly enters the user ID or password 3 times consecutively, an alarm will
be sent and connection will not be possible for 10 minutes.
•
Through system programming, it is possible to assign the Control Box port number and password.
•
The terminal emulator application must be running constantly. If the application is terminated, call records
that occur after the termination will be recorded in the Control Box's memory. However, if the number of
call records exceeds the Control Box's capacity, older records will be deleted. Also, when the application
restarts or is reconnected, duplicated call records may be output.
[Using SMDR with applications]
SMDR data can also be monitored by applications. For more information, see your application’s
documentation.
PC Programming Manual References
12.1 Control Box Configuration—[11-1] Maintenance—Main
Feature Manual References
5.1 Capacity of System Resources
2.6.1.2 Syslog Record Management
Description
By connecting the Control Box to a Syslog server over a LAN, it is possible to output local alarm information
(major alarms/minor alarms) to an external PC.
2.6.1 Record Log Features
Feature Manual
19
Содержание VL1700
Страница 4: ...Introduction 4 Feature Manual ...
Страница 6: ...List of Abbreviations 6 Feature Manual ...
Страница 9: ...Section 1 For Your Safety Feature Manual 9 ...
Страница 11: ...Section 2 Call Handling Features Feature Manual 11 ...
Страница 25: ...Section 3 Unified Messaging System Feature Manual 25 ...
Страница 32: ...3 2 2 Subscriber Features 32 Feature Manual ...
Страница 33: ...Section 4 System Configuration and Administration Features Feature Manual 33 ...
Страница 45: ...Section 5 Appendix Feature Manual 45 ...
Страница 47: ...Note Feature Manual 47 ...