Parameter
Description and available settings
Default
Terminal 1–4 Reception Code
Determines whether terminal 1–4 is a reception
terminal or a normal terminal (i.e., cannot be used as
a reception terminal).
[0]: NORMAL
[1]: RECEPTION
R
The lobby number of the reception room and the
reception terminal used in the reception must be
linked together in advance. When the number of
extension boxes used is increased, the DIP
switches of the extension boxes must be
configured.
[2]: GATE CALL (LOBBY GROUP 1)
[3]: GATE CALL (LOBBY GROUP 2)
[4]: GATE CALL (LOBBY GROUP 3)
0
(NORMAL)
*3
For systems that support enhanced features version 2 or later (page 92)
Lobby Station 1–3 — Building settings
Buildings must be registered. The settings can be used to change how many buildings are registered at each
lobby station.
Parameter
Description and available settings
Default
Building No.
Registers the building number of a building.
A maximum of 20 buildings can be registered.
A maximum of 3 digits can be used (1–999; 0 cannot
be registered).
1
Control Box No.
Determines the control box (1-4) to be linked to the
building number.
1
Lobby Station 1–3 — Room settings
Room settings can be configured to support a maximum of 2240 rooms.
Parameter
Description and available settings
Default
Room No.
Determines the room number.
(1–99999; 0 is displayed when the room is not
configured)
0
Resident Name
Determines the resident name for the corresponding
room number.
(20 characters max., uppercase letters only)
—
Building No.
Determines the building number for the
corresponding room number.
0
*4
For systems that support enhanced features version 3 or later (page 92)
An "Open code" for unlocking the lobby station can be configured for each resident.
Important:
R
To prevent intruders from entering the building, make sure to select open codes that are difficult to
guess, change them regularly, and keep them secret. Inform all relevant staff and residents of these
policies.
Lobby Station 1–3 — Room settings
Parameter
Description and available settings
Default
Room No.
Determines the room number.
(1–99999; 0 is displayed when the room is not
configured)
0
Resident Name
Determines the resident name for the corresponding
room number.
(20 characters max., uppercase letters only)
—
57
5. Programming