![Panasonic VL-V700 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/panasonic/vl-v700/vl-v700_installation-and-operating-instructions-manual_269796039.webp)
For systems that support enhanced features version 2 or later (page 92)
Up to 10 distribution boxes can be connected to each branch from the control box.
Distribution box
DIP switch
Repeat switch
H
1 2 3 4 5 6 7 8
ON
OFF
(off)
(off)
I
1 2 3 4 5 6 7 8
ON
OFF
(off)
(off)
J
1 2 3 4 5 6 7 8
ON
OFF
(off)
(on)
*1 Each DIP switch setting can only be used one time per branch.
*2 In distribution mode, the repeat switch of all distribution boxes in the branch is set to the "off" position.
*3 The terminate switch of the last distribution box in the branch is set to the "on" position. All others are set to the
"off" position.
*4
For systems that support enhanced features version 2 or later (page 92)
When connecting 8 or more distribution boxes, set the terminate switch of the 7th distribution box to the "off"
position.