How to make wiring connections:
While pressing on the button with a
pointed object such as a screwdriver,
insert the wire into the terminal
connector. (To disconnect a wire,
while pressing on the button, pull out
the wire.)
How to connect the DC cable:
1
Remove screw A and then remove the terminal cover.
2
Loosen screw B and push in the wires of the DC cable
to the terminal connectors (non-polar), then tighten the
screws.
3
Use the cable binder to secure the DC cable (double-
coated area) to the main monitor station.
4
Make sure to replace the terminal cover.
Mount the main monitor station to the mounting
bracket.
Connect the DC cable and wires.
Bare wire at tip
12 mm
32 mm
Cable binder
Screw B
Screws A
Bare wire at tip
Terminal Button
9 mm
Installing the main monitor station
Wiring from
door station
9 mm
Step 2
Step 3
1
Line up the tab on the bottom of the bracket with the
groove on the main monitor station (1).
2
Line up the tab on the top of the bracket with the groove
on the main monitor station, and push the main
monitor station down until it is secure (2).
(2)
(1)
Main
Main
Monitor Station Installation
Monitor Station Installation
Содержание VL-SWD501
Страница 1: ...2013 Wireless Video Intercom INSTALLATION GUIDE ...
Страница 3: ...System configuration and wiring System configuration and wiring ...
Страница 7: ...Door Station Installation Door Station Installation ...
Страница 16: ...Main Monitor Station Installation Main Monitor Station Installation ...
Страница 20: ...Power Supply Unit Installation Power Supply Unit Installation ...
Страница 23: ...Initial Setup Initial Setup ...
Страница 28: ...Installing Wireless Sensor Cameras Installing Wireless Sensor Cameras ...
Страница 40: ...Registering DECT Repeaters Registering DECT Repeaters ...
Страница 44: ...Specifications Specifications ...