background image

3.1 Installation cautions

Refer to the information found in 1  Important Information
(Page 3) before installing the product.

CAUTION

R

Always connect power cables to the appropriate
connection terminals. Incorrectly connecting the
power cables may damage the power supply unit.

R

To prevent the power cables from disconnecting and
to prevent electric shock, secure the power cables
using the included cable binders and attach the cable
covers.

R

If the wiring passes outdoors, use a conduit and a
surge protector.

R

If the wiring passes underground, use a conduit, and
do not make any connections underground.

R

Install the product securely adhering to the
instructions in this document to prevent it from falling
off the wall. Avoid installing onto low-strength walls,
such as gypsum board, ALC (autoclaved lightweight
concrete), concrete block, or veneer (less than
18 mm thick) walls.

3.2 Installing the power supply
unit

Required items

– Power supply unit
– Cable binders (included with power supply unit)
– Screws (included with power supply unit)
– Wires for AC and DC connection (user supplied)

See 3.2.5  Wire type and maximum wire length
(Page 9).

Installation location

R

The device must be installed inside an electrical
panel or cabinet.

R

A readily accessible disconnect device shall be
incorporated external to the equipment.
The external disconnect device must be certified, and
have a creepage and clearance distance of 3 mm or
more.

Installation methods

The following 2 methods can be used for installing the
power supply unit.
– mounting on a DIN rail (user supplied)
– attaching directly to a wall

7

3. . Installation

3. Installation

Содержание VL-PS2410

Страница 1: ...ection titled 1 1 Important safety information in particular This product is a separately sold power supply unit for use with Panasonic Video Intercom Systems Note to the installer R Please read this document carefully and install the product safely and correctly by following the instructions R Only use attachments accessories specified by the manufacturer R The installation shall be carried out i...

Страница 2: ...rtant information 4 1 5 General information 4 1 6 For India only 5 1 7 For Europe 5 2 Preparation 2 1 Included items 6 2 2 Specifications 6 2 3 Device diagrams 6 3 Installation 3 1 Installation cautions 7 3 2 Installing the power supply unit 7 3 3 Cleaning 10 3 4 Terms and illustrations in this document 10 2 Table of Contents ...

Страница 3: ... connections when the power outlet is turned on R Do not install the product and power supply unit in the following places Places where the product and power supply unit may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not push any objects through the openings of the product R If any of the following conditions occur disconnect the po...

Страница 4: ...you stop using the product remove it from the walls to prevent it from falling off R When power fails this product cannot be used R Panasonic may not be liable for damages due to external factors such as power failures 1 5 General information R In the event of problems you should contact your equipment supplier in the first instance R After removing the product and any included items from the pack...

Страница 5: ...dia only Declaration of Conformity with the requirements of the E Waste Management Rules The Product is in conformity with the requirements of the reduction of hazardous substances of the E Waste Rules The content of hazardous substance with the exemption of the applications listed in SCHEDULE II of the E Waste Rules 1 Lead Pb not over 0 1 by weight 2 Cadmium Cd not over 0 01 by weight 3 Mercury H...

Страница 6: ...ent Ambient temperature approx 0 C to 50 C Relative humidity non condensing up to 90 Installation method Attach to DIN rail Wall mount using included screws External material Flame retardant PC ABS resin 2 3 Device diagrams Example power supply unit with the cable cover removed A B H H I J K C D E F G A Output switch B DC OUT connection terminals 1 C DC OUT connection terminals 2 D DC OUT connecti...

Страница 7: ...ing off the wall Avoid installing onto low strength walls such as gypsum board ALC autoclaved lightweight concrete concrete block or veneer less than 18 mm thick walls 3 2 Installing the power supply unit Required items Power supply unit Cable binders included with power supply unit Screws included with power supply unit Wires for AC and DC connection user supplied See 3 2 5 Wire type and maximum ...

Страница 8: ... If the cables are not inserted all the way heat may be generated 4 Tighten the terminal screws to secure the AC and DC wires bare wire area to the terminals and then use the cable binders to secure the AC and DC wires jacketed area to the cable binder holes on the top and bottom on the power supply unit Example DC terminal 1 is used D C B B A A Example DC terminal 1 6 are used D C B B A A A Termi...

Страница 9: ...il and then release to lever R The bottom hook C will slide up securing the bottom of the power supply unit to the DIN rail B A C 3 2 4 Attaching directly to a wall Attach the power supply unit to the wall securely using the 2 mounting screws A A 3 2 5 Wire type and maximum wire length Wiring run Wire diameter Max length Power supply unit Connected device example lobby station distributor main mon...

Страница 10: ...uct with a slightly damp cloth Important R Do not use any cleaning products that contain alcohol polish powder powder soap benzine thinner wax petroleum or boiling water Also do not spray the product with insecticide glass cleaner or hair spray This may cause a change in colour or quality of the product 3 4 Terms and illustrations in this document R Model number suffixes e g the EX in VL PS2410EX ...

Страница 11: ...11 Notes ...

Страница 12: ... Panasonic Corporation 2018 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com PNQP1390ZA C0118MG0 ...