Installing the door station
Important:
L
On the bottom surface of the door station, there are holes to allow water to drain.
Do not cover them up when installing.
1
Remove the mounting base.
A
Open the screw
cover.
T
Screwdriver
Mounting base
B
Loosen the
mounting screw.
Water drain
holes
2
Attach the mounting base to the wall securely using the wood screws (3.8 mm x 20 mm).
L
Install the mounting base on a vertical
fl
at wall.
L
Before drilling, refer to “Before installation” for installation location.
83.5 mm
Wall
Wire (Not included)
Mounting base
Wood screws
3
Adjust the camera angle using the camera angle control lever.
L
The angle can also be adjusted to the left
or upper left.
<Examples of camera angle>
<Facing forwards>
<Facing upwards>
<Facing right>
<Facing upper right>
Rear view
Camera angle
control lever
Left
(maximum 15°)
Right
(maximum 15°)
Upwards
(maximum 15°)
Important:
L
When the camera angle is adjusted to the upper left or upper right, the image may be slightly
distorted.
4
Connect the wire, then mount the door station to the mounting base.
C
Fasten the screw, then
close the screw cover.
A
Unscrew the screws.
Push in the wire to the terminal connectors
(non polar), then tightly fasten the screws.
Wire (connecting to the main monitor station)
B
Mount the door station to
the mounting base.
Installing the main monitor station
1
Attach the mounting bracket to the wall securely using the wood screws (4 mm x 16 mm).
L
Install the mounting bracket on a vertical
fl
at wall.
L
Before drilling, refer to “Before installation” for installation location.
83.5 mm
Wood screws
Wall
Wire (Not included)
Mounting bracket
2
Attach the wires connected to the door station to the terminal connector.
L
Connect the wire correctly according to “Wiring schematic diagram”.
L
While pressing on the button with a pointed object such as a screwdriver, insert the wire into
the terminal connector. (To disconnect a wire, press on the button while pulling out.)
Wire from the door station
Stripped end of
the wire
9 mm
Terminal
connector
Button
3
Mount the main monitor station to the mounting bracket.
A
Fit into position as shown in the
fi
gure.
B
Push the main monitor station down until it is secure.
B
A
4
Connect the plug into an AC outlet (100 – 240 V AC).
To connect the plug to the power outlet which is not easily accessible
Important:
L
If you want to connect the plug to the power outlet which is in the wall or is not easily
accessible, install a main disconnect device near the main monitor station.
L
Use a main disconnect device with minimum 3 mm contact spacing inside the device and
showing “ON” and ”OFF”.
To use an existing wire in your home
1
Be sure to turn off the power and con
fi
rm that the wire type is CAT-3 (ø0.5) or 22 AWG
(ø0.65). If the wire type is not CAT-3 (ø0.5) or 22 AWG (ø0.65), change the wire to either of the
speci
fi
ed wire types.
2
Install the main monitor station and the door station.
3
Turn on the power.