16
Troubleshooting
Indicator
Problem
Cause & Solution
Page
The POWER indicator is
turned off.
L
The power is not turned on. Connect the AC
adaptor.
14
The STATUS indicator is
turned off.
L
The repeater has not been registered. Register it
to the main monitor station.
12
The STATUS indicator is
flashing in red.
L
The power of the main monitor station is not
turned on. Turn it on.
L
The repeater is out of range. Install it in a
location where the STATUS indicator lights in
green.
—
14
The IN USE indicator
lights in green.
L
The repeater is relaying radio waves.
—
The IN USE indicator is
turned off when using the
sub monitor station.
L
The sub monitor station is being used in a place
where the radio signal is stronger from the main
monitor station than the repeater. (This is not
malfunction.)
6
Others
Problem
Cause & Solution
Page
Can I register the
repeater to another main
monitor station?
L
You cannot register one repeater to two or more
main monitor stations. To register to another
main monitor station, another repeater is
needed.
—
Can I locate the repeater
in a place where the
STATUS indicator does
not light in green?
L
You can install the repeater in a location where
the STATUS indicator lights in amber or red,
but sound cuts in and out, or calls may be
disconnected. We recommend a location where
the indicator lights in green.
14
Can I locate the repeater
outdoors?
L
Do not install the repeater outdoors.
—
The repeater does not
improve the radio signal.
L
The STATUS indicator lights in amber or red,
or is flashing in red. Reinstall the repeater in a
location where the indicator lights in green.
L
The repeater has been installed near the main
monitor station. In this location, the repeater
cannot work effectively because the sub monitor
station receives radio waves from only the main
monitor station. Reinstall it in a location near to
where the sub monitor station is used.
14
6
PNQX7534ZA_VL-FAN2_CS3.indd 16
9/16/2015 4:15:02 PM