Slide #38

5 Blinks Error Code (All Models)

Trouble Mode

5V SOS

Defective Board

P, C, A,SC, SS board or Panel

Disconnect the TV. Measure the resistance 

between pin 1 of connector P35 on the P 

board and ground (Chassis).

Yes

Proceed to more extensive troubleshooting 

of the slides that follow. 

No

Is there a 

short to 

ground?

Panel

Note: 

Even though it 

does not happen often, 

the 5 blinks shutdown

can also be caused by

one of the C boards

Warning: 

Disconnect AC Power prior to 

making any disconnection or connection.

Does the power 

supply

makes a “chirp” 

noise at plug in?

Start Here

Yes

No

Yes

No

Is there a 

short to 

ground?

Replace

the SS board

Replace

the SC board

Disconnect the TV. Disconnect 

P2 and P11 on the P board 

Measure the resistance between 

pin 1 of connector SS11 on the 

SS board and ground (Chassis).

Yes

No

Is there a 

short to 

ground?

All other 2009 Models

TC-P42G10

TC-P46G10

TC-50G10

TC-P54G10

Measure the resistance between 

pin 1 of connector SC2 on the SC 

board and ground (Chassis).

Replace

the P board

Start Here

If the power LED continues to blink even after the TV is unplugged, press and hold the power 
switch on the TV for a few seconds until the LED turns off.

Содержание Viera TC-P42X1

Страница 1: ...TV 12th Generation Model TC P42PX1 TC P42X1 TC P50X1 TC P42C1 TC P50C1 TC P42S1 TC P46S1 TC P50S1 TC P54S1 TC P42U1 TC P46U1 TC P50U1 TC P42G10 TC P46G10 TC P50G10 TC P54G10 TC P42G15 TC P46G15 TC P50...

Страница 2: ...to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in...

Страница 3: ...e Test All Models Except TC 50PX14 TC P50X1 TC P50C1 30 SC Board Resistance Test Models TC 50PX14 TC P50X1 TC P50C1 31 1 Blink Error Code All Models 32 2 Blinks Error Code All Models 33 2 Blinks Error...

Страница 4: ...before shutdown 2 Check if the power comes up after disconnecting the board under suspicion If power comes up after disconnecting a board the board is defective Power comes up equals no shutdown 2 Tro...

Страница 5: ...Slide 5 HD boards Layout TC P42X1...

Страница 6: ...Slide 6 Full HD boards Layout TC P42S1...

Страница 7: ...Slide 7 Full HD Connector s Location TC P42S1...

Страница 8: ...Troubleshooting Shutdown Problems CAUTION Some steps require removal of connectors and sometimes PC boards removal Do not let the TV run for more than 30 seconds while connectors or boards are discon...

Страница 9: ...ll flash a pattern indicating the circuit that has failed If the power LED continues to blink even after the TV is unplugged press and hold the power switch on the TV for a few seconds until the LED t...

Страница 10: ...Slide 10 Shutdown Detect Block Diagram...

Страница 11: ...Slide 11 HD Panel Drive SOS Detect Block Diagram TC P42X1...

Страница 12: ...Slide 12 Full HD Panel Drive SOS Detect Block Diagram TC P42S1...

Страница 13: ...A32 Unplugged SOS 6 Blinks A20 Unplugged A31 Unplugged A32 Unplugged TV Stays On With Black Screen HD Models Do not remove any connectors from any of the PC boards unless instructed to do so CAUTION S...

Страница 14: ...d OK SC20 Unplugged SS11 Unplugged OK Model TC P42X1 SC Board Isolation Connector Connector Connector Connector On SS board Result SC2 Unplugged SOS 7 Blinks SC3 Unplugged SOS 6 Blinks SC20 Unplugged...

Страница 15: ...6 Blinks SC20 Unplugged SS11 Unplugged SOS 6 Blinks Model TC P50X1 SC Board Isolation Connector On C1 board Connector Connector Connector On SS board Result SC3 Unplugged SOS 6 Blinks SC20 Unplugged S...

Страница 16: ...ged A31 Unplugged SOS 6 Blinks A33 Unplugged A32 Unplugged OK A31 Unplugged A32 Unplugged SOS 6 Blinks A33 Unplugged A31 Unplugged A32 Unplugged TV Stays On With Black Screen Full HD Models CAUTION So...

Страница 17: ...ult SS11 Unplugged SC2 Unplugged 7 Blinks SS11 Unplugged SC20 Unplugged 6 Blinks SS11 Unplugged SC2 Unplugged SC20 Unplugged 6 Blinks SS11 Unplugged SS33 Unplugged SC2 Unplugged 7 Blinks SS11 Unplugge...

Страница 18: ...between VF_GND and CHA on the SC board This floats point CHA triggering the SOS7 detect circuit This outputs a high to the A board through connector SC20 triggering shutdown A new SC test fixture Jig...

Страница 19: ...en pins 1 and 2 of connector SC50 on the SC board Note If the SC jig is not available install a jumper between pins 1 and 2 of connector SC50 on the SC board Remove the jig or the jumper after complet...

Страница 20: ...e 20 Procedure to Isolate both SU SD at the Same Time If the power LED continues to blink even after the TV is unplugged press and hold the power switch on the TV for a few seconds until the LED turns...

Страница 21: ...connector SC50 on the SC board Note If the SC jig is not available install a jumper between pins 1 and 2 of connector SC50 on the SC board Remove the jig or jumper after completing isolation procedure...

Страница 22: ...2 of connector SC50 on the SC board Note If the SC jig is not available install a jumper between pins 1 and 2 of connector SC50 on the SC board Remove the jig or jumper after completing isolation pro...

Страница 23: ...How to Easily Gain Access to the SS board SCREW SCREW SCREW Remove the 3 screws that hold the A board assembly in place Let the A board assembly rest on the speaker s magnet to gain access to the SS b...

Страница 24: ...e the 4 screws holding the front panel in place Remove the cables from the speakers Remove the screws from the speakers 2 each Remove the speakers Remove the front cabinet Note To remove the front cab...

Страница 25: ...on the SU and SD boards for blown hole on the surface Note In some models it is not possible to check if these ICs are blown because they use surface mount heat sinks that are glued to the surface of...

Страница 26: ...ds Resistance Test Procedure Note The result of the resistance test determine if the boards are bad but it does not determine if they are 100 good For this reason after performing a resistance test we...

Страница 27: ...te A low resistance reading indicates a defective SU board Preparation Disconnect AC Power prior to making any disconnection or connection Wait at least 2 minutes before the removal of any connector N...

Страница 28: ...1Mega ohms Note A low resistance reading indicates a defective SD board Preparation Disconnect AC Power prior to making any disconnection or connection Wait at least 2 minutes before the removal of a...

Страница 29: ...a ohms Note A low resistance reading indicates a defective SD board Preparation Disconnect AC Power prior to making any disconnection or connection Wait at least 2 minutes before the removal of any co...

Страница 30: ...is approximately 2 9Kilo ohms and approx 5 7Kilo ohms for pin 5 Note A low resistance reading indicates a defective SC board Preparation Disconnect AC Power prior to making any disconnection or conne...

Страница 31: ...proximately 2 9Kilo ohms and approx 5 7Kilo ohms for pin 7 Note A low resistance reading indicates a defective SC board Preparation Disconnect AC Power prior to making any disconnection or connection...

Страница 32: ...5V at pin 9 of connector P25 A25 Make sure that connectors P25 and D25 are properly seated Replace the P board Is there continuity between pin 9 of connector P25 and pin 5 of connector P7 on the P bo...

Страница 33: ...isconnection or connection 1 Missing P15V 2 A short of the P15V 3 Wrong diagnostic by the A board These 3 conditions can cause the TV to shutdown and the power LED to blink 2 times If the power LED co...

Страница 34: ...nd P25 on the P board Measure the resistance between pin 1 of connector P6 and ground Chassis Is there a short circuit No Yes Replace The P board Reconnect P11 and measure the resistance between pin 1...

Страница 35: ...rd A Board Replace the A board Warning Disconnect AC Power prior to making any disconnection or connection Start Here If the power LED continues to blink even after the TV is unplugged press and hold...

Страница 36: ...ere a short to ground Replace the SS board Replace the SC board Disconnect the TV Disconnect P2 and P11 on the P board Measure the resistance between pin 1 of connector SS11 on the SS board and ground...

Страница 37: ...5V 2 A short of the P5V 3 A short of the Vda line Note missing Vda from the P board does not cause 5 blinks 4 Wrong diagnostic by the A board These 4 conditions can cause the TV to shut down and the p...

Страница 38: ...ection or connection Does the power supply makes a chirp noise at plug in Start Here Yes No Yes No Is there a short to ground Replace the SS board Replace the SC board Disconnect the TV Disconnect P2...

Страница 39: ...and disconnect SC20 on the SC board Measure the resistance between pin 5 of connector P25 on the P board and ground Chassis Yes No Is there a short to ground Replace the SC board Reconnect SC20 and d...

Страница 40: ...If the C boards are ok replace the Panel Note B The C board can be checked individually Reconnect the ribbon cables from the A board A31 A32 and A20 for HD models A33 Disconnect the flex cables betwe...

Страница 41: ...to making any disconnection or connection LIST OF MODELS TC P42X1 TC P42C1 TC 42PX14 TC P50X1 TC P50C1 TC 50PX14 CAUTION The TV power should not be turned on while SC2 is disconnected This could damag...

Страница 42: ...oards can be defective Follow procedure on slides 17 21 to determine which of the 2 boards is defective No Yes Did the number of blinks change Replace the A board No Yes Is the power LED still blinkin...

Страница 43: ...ber of blinks change Replace the A board Is the power LED still blinking NOTE The SS board may had just become damaged Shorted Vsus LIST OF MODELS TC P50X1 TC P50C1 TC 50PX14 Start Here 10 times CAUTI...

Страница 44: ...prior to making any disconnection or connection LIST OF MODELS TC P42S1 TC P42G10 TC P42U1 TC P42U1 TC 42PS14 TC P46S1 TC P46G10 TC P46U1 TC P50S1 TC P50G10 TC P50U1 TC P50V10 TC 50PS14 TC P54S1 TC 54...

Страница 45: ...C P42U1 TC P42U1 TC 42PS14 TC P46S1 TC P46G10 TC P46U1 TC P50S1 TC P50G10 TC P50U1 TC P50V10 TC 50PS14 TC P54S1 TC 54G10 Unplug the TV and reconnect connector SC20 and the ribbon cable between the C b...

Страница 46: ...onds until the LED turns off Remove the front cabinet and expose the panel to a bright light for a thorough visual inspection Check for cracks and blown pixels or any other abnormalities Check the ICs...

Страница 47: ...ow this procedure when all 3 boards check OK Replace the SU SD and SC boards Replace the SC board Go to the next slide Go to the Slide 16 1 Remove the front cabinet and check for cracks and blown pixe...

Страница 48: ...ug in the TV and press the power switch No Replace the SU and the SD boards Does the TV shut down and the power LED blink 7 times A Start Here If the power LED continues to blink even after the TV is...

Страница 49: ...place the SC and the A boards Unplug the TV and reconnect connector SC20 and the SU and SD boards Measure the resistance between pin 1 of P2 SC2 or P11 SS11 Vsus and ground Is there a short circuit Ye...

Страница 50: ...Code HD Models SS_Flexible Printed Circuit FPC _Detect SOS8_SS TC P42X1 If the power LED continues to blink even after the TV is unplugged press and hold the power switch on the TV for a few seconds...

Страница 51: ...rd are properly seated 50 HD Models TC P50X1 TC P50C1 TC 50PX14 Make sure that connectors SS53 SS55 SS56 and SS21 on the SS board and connectors SS24 and SS58 on the SS2 board are properly seated Note...

Страница 52: ...the panel and the SS SS2 boards Make sure they are properly seated and that the connectors are properly locked Unplug the TV and reconnect SS23 Use a volt meter and place the positive probe on the an...

Страница 53: ...Slide 53 8 Blinks Error Code Full HD Models If the power LED continues to blink even after the TV is unplugged press and hold the power switch on the TV for a few seconds until the LED turns off...

Страница 54: ...e that connectors SS61 SS64 and SS21 on the SS board and connectors SS24 and SS58 on the SS2 board are properly seated 50 and 54 Full HD Models TC P50S1 TC P50G10 TC P50U1 TC P50V10 TC 50PS14 TC P54S1...

Страница 55: ...problem Disconnect the TV Use a volt meter and place the positive probe on the anode of D280 on the SS board See previous slide for location while the negative probe is grounded Plug in the TV and tur...

Страница 56: ...efective Board A Board Replace the A board Warning Disconnect AC Power prior to making any disconnection or connection If the power LED continues to blink even after the TV is unplugged press and hold...

Страница 57: ...erations there s no 10 blinks error code at plug in for 2009 models When the A board is replaced the TV turns on in aging mode by itself at plug in What can possibly cause 10 blinks A Missing Shorted...

Страница 58: ...a short circuit Yes No Replace the SC board See Note 2 See Note 3 Replace the P board Is there 15V at pin 7 of connector P6 at the moment the relay clicks No Yes Replace the A board Note 2 If the SS...

Страница 59: ...ure that connectors SC20 A33 SC2 P2 P6 A6 are properly seated What can possibly cause 10 blinks A Missing Shorted F_15V B Shorted Vsus C Missing Shorted SUB5V SUB9V BT30V D IC1100 IC9003 IC9004 E Unpl...

Страница 60: ...nectors SS11 SS33 SC2 and SC20 Plug in the TV and press the power switch No Yes Replace the P board LIST OF MODELS TC P42S1 TC P42G10 TC P42U1 TC P42U1 TC 42PS14 TC P46S1 TC P46G10 TC P46U1 TC P50S1 T...

Страница 61: ...up and stay on No Yes Replace Fan A Unplug the TV and reconnect Fan Disconnect the connector from Fan B Place a jumper wire NOTE A between the center pin Black wire and the pin with the yellow wire o...

Страница 62: ...o Yes If the speakers wires are not pinched Replace the speaker Replace the A board Trouble Mode Audio SOS Defective Board Possibility A Board Pinched speaker wire Speaker Warning Disconnect AC Power...

Страница 63: ...Disconnect AC Power prior to making any disconnection or connection Communication Error between IC8001 and IC1100 Replace the A board If the power LED continues to blink even after the TV is unplugge...

Страница 64: ...TV and reconnect P6 and P25 only Plug in the TV and press the power switch Unplug the TV and reconnect C11 Disconnect C14 on the C1 board and plug in the TV Press the power switch It the TV turning on...

Страница 65: ...the power with the POWER button on the main unit or the POWER button on the remote control Key command 1 button Main items Selection in forward direction 2 button Main items Selection in reverse dire...

Страница 66: ...the TV for 5 seconds or disconnect the AC cord from the wall outlet To Exit the Self Check Mode Press and hold the Power button on the TV for 5 seconds or disconnect the AC cord from the wall outlet T...

Страница 67: ...ry shipment setting To reset the TV Press and hold the VOLUME button on the TV and press the MENU button on the remote control for more than 3 seconds Note All customer programmed parameters will be e...

Страница 68: ...on The first 5 numbers out of the two 5 digits groups to the right of Status2 are used to determine the SOS history SOS History A history of SOS occurrences can be found under the Version Menu 0 0 0 0...

Страница 69: ...e 2 No picture 2 Basic concept of determining the defective board 1 Which area is the symptom displayed on the screen A Part of the screen B All over the screen 3 Adjustment after PCB exchange 1 After...

Страница 70: ...ure gas leakage started at the left top corner Finally gas leakage will lead to the symptom No picture with buzz noise Start Upper or Lower half from front view Upper half Lower half Both area SU Boar...