Slide #15
Power LED’s Response to Connectors Removal (50” HD Models)
Model:
TC-P42X1
(SS Board Isolation)
Connector
Connector
Connector
Result
SS11
Unplugged
SOS 6 Blinks
SS3
Unplugged
SOS 6 Blinks
SS23
Unplugged
OK
SS11
Unplugged
SS3
Unplugged
SOS 6 Blinks
SS11
Unplugged
SS23
Unplugged
SOS 6 Blinks
SS3
Unplugged
SS23
Unplugged
SOS 6 Blinks
SS11
Unplugged
SS3
Unplugged
SS23
Unplugged
SOS 6 Blinks
SC3
Unplugged
SC20
Unplugged
SS11
Unplugged
SOS 6 Blinks
SC20
Unplugged
SS11
Unplugged
SOS 6 Blinks
SC20
Unplugged
SS11
Unplugged
SOS 6 Blinks
Model:
TC-P50X1
(SC Board Isolation)
Connector
On C1
board
Connector Connector
Connector
On SS
board
Result
SC3
Unplugged
SOS 6 Blinks
SC20
Unplugged
SOS 6 Blinks
SC3
Unplugged
SC20
Unplugged
SS11
Unplugged
SOS 8 Blinks
C10
Unplugged
SC20
Unplugged
SS11
Unplugged
OK
50”HD Models
CAUTION:
Some steps require
removal of connectors and
sometimes PC boards removal.
Do not let the TV run for more
than 30 seconds while
connectors or boards are
disconnected.
Do not remove any connectors
from any of the PC boards
unless instructed to do so.
CAUTION:
The TV power should not be
turned on while SC2 is disconnected. This
could damage the SS board.
Содержание Viera TC-P42X1
Страница 5: ...Slide 5 HD boards Layout TC P42X1...
Страница 6: ...Slide 6 Full HD boards Layout TC P42S1...
Страница 7: ...Slide 7 Full HD Connector s Location TC P42S1...
Страница 10: ...Slide 10 Shutdown Detect Block Diagram...
Страница 11: ...Slide 11 HD Panel Drive SOS Detect Block Diagram TC P42X1...
Страница 12: ...Slide 12 Full HD Panel Drive SOS Detect Block Diagram TC P42S1...
Страница 71: ...Slide 71 The End...