9
2 Service Modes
2.1.
Service Modes (For Facsimile)
2.1.1.
Service Mode 1 (Function Parameter Setting)
Function Parameter Table
No.
Parameter
Selections
Function
130 BUSY-ACK
TIMING
(Except UF-580/
780)
• In Busy
• After Busy
• While Busy
Selects the signal timing between the BUSY and
ACK signal in Printer Interface Mode.
131 CMD RCV GRD
TIMER
(Except UF-580/
780)
1 min.
~
15 min.
Selects the Guard Timer between each GDI
Command in Printer Interface Mode.
132 PRT DATA
TIMER
(Except UF-580/
780)
1 min.
~
15 min.
Selects the Guard Timer between each GDI Data
Frame in Printer Interface Mode.
133 COLLATION
(PRT)
(Except UF-580/
780)
1 = Off
2 = On
3 = Auto
Selects the Print Collation in Printer Interface Mode.
When “Auto” is selected, print collation will operate
according to the setting in Fax Parameter #65.
134 COLLATION
(PC I/F)
(Except UF-580/
780)
1 = Off
2 = On
3 = Auto
Selects the Print Collation in PC Interface Mode.
When “Auto” is selected, print collation will operate
according to the setting in Fax Parameter #65.