Trouble Diagnosis
1. Contents of Remote Controller
Switch Alarm Display
ON:
Blinking:
OFF:
Possible cause of malfunction
Wired
remote
control
display
Wireless
remote controller
receiver display
Operation
Timer
Standby
for heating
Serial
communication
errors
Mis-setting
Remote controller is detecting
error signal from indoor unit.
Error in receiving serial communication signal.
(Signal from main indoor unit in case of group control)
Ex: Auto address is not completed.
Error in receiving serial communication signal.
When turning on the power supply, the number of connected
indoor units does not correspond to the number set.
(Except R.C. address is “0.”)
Error in transmitting serial communication signal.
Indoor unit is detecting error signal from remote controller (and system controller).
Indoor unit is detecting error
signal from main outdoor unit.
Error of the main outdoor unit in receiving serial
communication signal from the indoor unit.
Improper setting of indoor unit
or remote controller.
Indoor unit address setting is duplicated.
<E01>
<E02>
<<E03>>
E04
<E06>
E08
<<E09>>
Remote controller address connector (RCU. ADR) is
duplicated. (Duplication of main remote controller)
During auto address setting,
number of connected units
does not correspond to
number set.
Starting auto address setting is prohibited.
This alarm message shows that the auto address connector
CN30 is shorted while other RC line is executing auto
address operation.
E12
When turning on the power
supply, number of connected
units does not correspond to
number set.
(Except R.C. address is “0.”)
Error of main indoor unit in receiving serial communication
signal from sub indoor units.
E18
Error in auto address setting. (Number of connected indoor
units is less than the number set.)
E15
Error in auto address setting. (Number of connected indoor
units is more than the number set.)
E16
No indoor unit is connected during auto address setting.
E20
Main outdoor unit is detecting error signal from sub outdoor
unit.
Serial transmission failure of outdoor unit.
Communication failure with MDC
E24
E25
E30
E31
Error of outdoor unit address setting.
E26
The number of connected main and sub outdoor units do not
correspond to the number set at main outdoor unit PCB.
E27
Improper wiring between main outdoor unit and sub-unit.
Operating lamp
blinking
Heating ready lamp
blinking
Operating lamp
blinking
Heating ready lamp
blinking
Error of sub outdoor unit in receiving serial communication
signal from main outdoor unit.
E29
L02
This alarm message shows when an indoor unit for
multiple-use is not connected to the outdoor unit.
Improper setting.
Duplication of main indoor unit address setting in group
control.
<L03>
Operating and heating
ready lamps blinking
simultaneously
Group control wiring is connected to individual control indoor
unit.
Indoor unit address is not set.
L07
L08
<<L09>>
Capacity code of indoor unit is not set.
Mis-matched connection of outdoor units that have different
kinds of refrigerant.
L17
Incorrect wiring of remote group control wiring
(in case of shared solenoid valve kit)
L11
Duplication of outdoor R.C. address setting.
L04
Capacity code of outdoor unit is not set.
L10
Continued
Operating and heating
ready lamps blinking
simultaneously