background image

4

WARNING

Stop using the product when any 

abnormality/failure occurs and 

disconnect the power plug or turn 

off the power switch and breaker.

(Risk of smoke/fire/electric shock)

Examples of abnormality/failure:

• 

The ELCB trips frequently.

• 

The product sometimes does not 

start when turned on.

• 

The power is sometimes 

disconnected when the cord is 

moved.

• 

Burnt odor or abnormal noise is 

detected during operation.

• 

The body is deformed or 

abnormally hot.

• 

Water leaks from the indoor unit.

• 

Power cord or plug becomes 

abnormally hot.

• 

Fan speed cannot be controlled.

• 

The unit stops running 

immediately even if it is switched 

on for operation.

• 

The fan does not stop even if the 

operation is stopped.

Contact immediately your local 

dealer for maintenance/repair.

Do not sit or step on the unit.  

You may fall down accidentally.

This appliance is intended to be used by 

expert or trained users in shops, in light 

industry and on farms, or for commercial 

use by lay persons.
This appliance is not intended for use 

by persons (including children) with 

reduced physical, sensory or mental 

capabilities, or lack of experience 

and knowledge, unless they have 

been given supervision or instruction 

concerning use of the appliance by 

a person responsible for their safety.

Children should be supervised to ensure 

that they do not play with the appliance.

Keep the fire alarm and the air outlet at 

least 1.5m away from the unit.
Do not cool or heat the room too much 

if babies or invalids are present.
Do not turn the air conditioner on and 

off from the power mains switch. Use 

the ON/OFF operation button.
Do not stick anything into the air 

outlet of the outdoor unit. This is 

dangerous because the fan is 

rotating at high speed.
Do not touch the air inlet or the 

sharp aluminum fins of the 

outdoor unit. You may get 

injured.
Do not stick any object 

into the FAN CASE. You 

may be injured and the unit 

may be damaged.

CAUTION

• The appliance shall be stored so as to prevent mechanical damage from occurring.

• 

The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers 

after a few minutes.

NOTICE

The appliance shall be stored 

in a room without continuously 

operating open flames (for 

example: an operating gas 

appliance) and ignition sources 

(for example: an operating electric 

heater).

OI_00_300394_en.indb   4

2017/12/21   9:23:24

Содержание U-100PZ2R5

Страница 1: ...unit lineup This booklet is the operating instructions for outdoor unit Regarding the indoor unit see the operating instructions supplied with the indoor unit INDOOR UNIT 4 Way Cassette Wall Mounted Ceiling Low Silhouette Ducted Ducted Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan ACXF55 15060 Before operating the unit read these operating instructions thoroughly and keep them for futu...

Страница 2: ...ecified type may cause product damage burst and injury etc This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or oil heating appliances in the same room which consume a lot of oxygen from the air Otherwise there is a risk of suffocation in an extreme case Never use or store gasoline or other flammable vapor or liqu...

Страница 3: ...t separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Be aware that refrigerants may not contain an od...

Страница 4: ...or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Keep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids ...

Страница 5: ...lectrician for details z z Each unit must be properly grounded with a ground or earth wire or through the supply wiring z z Wiring must be done by a qualified electrician Operation Preparation Turn the power mains on 5 hours before the start of operation For warm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch...

Страница 6: ...nal Remote Controller Maintenance Refer to the Operating Instructions attached to the indoor unit Troubleshooting Refer to the Operating Instructions attached to the indoor unit Wireless Remote Controller A Model No CZ RTC4 For all indoor units Timer Remote Controller Read the Operating Instructions included with the Remote Controller High spec Wired Remote Controller For all indoor units Optional...

Страница 7: ...B 15 C 24 C DB Model Name U 100PZ2R8 U 125PZ2R8 U 140PZ2R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Sound pressure level Cooling Heating dB A 52 52 55 55 56 56 Sound power level Cooling Heating dB A 68 67 70 70 71 71 Unit dimensions H W D mm 996 980 370 996 980 370 996 980 370 Net wei...

Страница 8: ...Panasonic Corporation Website http www panasonic com Printed in Malaysia Panasonic Corporation 2017 ACXF55 15060 DC1217 0 ...

Отзывы: