1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
W
and 5.2M
W
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Figure 1
1.1.2. Leakage Current Hot Check (See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
W
, 10 watts resistor, in parallel with a 0.15µF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
2
TY-FB10WPE / TY-FB10WPU
Содержание TY-FB10WPE
Страница 6: ...NOTE 6 TY FB10WPE TY FB10WPU ...
Страница 9: ...6 Block and Schematic Diagram 6 1 Schematic Diagram Notes TY FB10WPE TY FB10WPU 9 ...
Страница 16: ...NOTE TY FB10WPE TY FB10WPU 16 ...
Страница 17: ...7 Exploded Views Replacement Parts List 7 1 Packing Exploded Views 17 TY FB10WPE TY FB10WPU ...
Страница 18: ...7 2 Accessories 18 TY FB10WPE TY FB10WPU ...
Страница 19: ...7 3 Replacement Parts List Notes 19 TY FB10WPE TY FB10WPU ...