10. Service Mode Function
MPU controls the functions switching for each IC through IIC bus in this chassis. The following
setting and adjustment can be adjusted by remote control in Service Mode.
10.1. How to enter SERVICE 1
1. Set OFF TIMER to 15,30.....
2. Set VOLUME to MINIMUM.Press the F button on the TV set to
select VOLUME, simultaneously press RECALL button on remote
control and DOWN button [-/v ] on the TV set.
10.2. How to enter SERVICE 2
1. Select the "Sub-Brightness" under Service 1.
2. Simultaneously press MUTE button on remote control and DOWN
button on the TV set.
Note:
To exit to Service mode, press N button or POWER button on
remote control.
26