Option Menu for GPH10D series
GPH10D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful for
special function required customers. This should be set at the installation stage.
Option menus
default setting
Contents
Off-timer function
Enable
Off-timer operation Enable/Disable.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode
selection while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume
control while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Studio W/B
Off
Set warm mode color temperature to 3,200 Kelvin.
Advanced PIP
Off
Off: Sets normal two screen display mode.
On: Sets Advanced PIP mode.
Display size
Off
Adjusts the image display size on screen.
On: Sets the image display size approximately 95% of the normal image
display.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume
up/down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Status,
Surround, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
V. Installation
Off
V. Installation function On/Off (Not used)
Rotate
Off
The image rotates 180 degrees (up-down)
Serial Slot Select
Slot1
Selects the slot which communicates serial.
Note:
The setting of an external command can be set only from the fixed
serial terminal.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R“ button on the remote control and hold for more than 5 seconds.
The “SHIPPING” menu is displayed and the lock is released when it disappears.
38
TH-50PH10UK
Содержание TH50PH10UK - 50" PLASMA TELEVISION
Страница 4: ...1 Applicable signals 4 TH 50PH10UK ...
Страница 18: ...18 TH 50PH10UK ...
Страница 19: ...7 Location of Lead Wiring 7 1 Lead Wiring 1 The lead wiring is dressed as shown in figure 19 TH 50PH10UK ...
Страница 20: ...7 2 Lead Wiring 2 The lead wiring is dressed as shown in figure 20 TH 50PH10UK ...
Страница 27: ...9 2 IIC mode structure following items value is sample data 27 TH 50PH10UK ...
Страница 29: ...29 TH 50PH10UK ...
Страница 31: ...31 TH 50PH10UK ...
Страница 34: ...3 Remarks Above Fan function is operated during the fans are installed 34 TH 50PH10UK ...
Страница 37: ...12 Option Setting 37 TH 50PH10UK ...
Страница 63: ...14 Schematic and Block Diagram 14 1 Schematic Diagram Notes TH 50PH10UK 63 ...
Страница 115: ...15 Parts Location 15 1 Exploded View 15 1 1 The main mechanical parts relation 115 TH 50PH10UK ...
Страница 116: ...15 1 2 Escutcheon part location enlarged views of lower left side 15 2 Fan part location enlarged views 116 TH 50PH10UK ...
Страница 117: ...15 3 Cable relation 117 TH 50PH10UK ...
Страница 118: ...15 4 Packing summary 118 TH 50PH10UK ...
Страница 120: ...17 1 Replacement Parts List Notes 17 Replacement Parts List 120 TH 50PH10UK ...