![Panasonic TH50PF9UK - 50](http://html.mh-extra.com/html/panasonic/th50pf9uk-50-plasma-panel/th50pf9uk-50-plasma-panel_service-manual_274802030.webp)
10 Adjustment
10.1. RGB white balance adjustment
Instrument Name
Connection
Remarks
·
RGB VGA W / B pattern
·
Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
User setting: Normal
(Picture menu: Standard)
Procedure
Remarks
[condition]
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Set COMPONET / RGB-IN SELECT to RGB.
2.
Select the IIC mode “PANEL W / B Adj.” item.
3.
Check that the color temperature is “COOL (High)”.
4.
Output a white balance pattern.
5.
Touch the signal receiver of color analyzer to the highlight window’s center.
6.
Fix G drive at E0h and adjust B drive and R drive so x, y become the “Color temperature
High” in the below table.
7.
Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
8.
Set color temperature to “NORMAL (Medium)”.
9.
Fix G drive at E0h and adjust B drive and R drive so the highlight window’s x, y becomes
the “Color temperature Medium” in the below table.
10. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
11. Set color temperature to “WARM (Low)”.
12. Set G drive to E0h and adjust B drive and R drive so the highlight window’s x, y become
the “Color temperature Low” shown in the below table.
13. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
14. Copy the R drive, G drive and B drive data in NTSC, PAL DVI region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Picture: 25
Aspect: Full
Position and size: Normal
·
Highlight section Signal amplitude 75%
·
Cutoff standard G: 80h
·
Drive standard G: E0h
30
TH-50PF9UK
Содержание TH50PF9UK - 50" Plasma Panel
Страница 4: ...1 Applicable signals 4 TH 50PF9UK ...
Страница 19: ...7 Location of Lead Wiring 19 TH 50PF9UK ...
Страница 20: ...20 TH 50PF9UK ...
Страница 21: ...21 TH 50PF9UK ...
Страница 24: ...8 4 Adjustment Volume Location 8 5 Test Point Location 24 TH 50PF9UK ...
Страница 29: ...9 2 IIC mode structure following items value is sample data 29 TH 50PF9UK ...
Страница 31: ...31 TH 50PF9UK ...
Страница 33: ...33 TH 50PF9UK ...
Страница 39: ...12 Option Setting 39 TH 50PF9UK ...
Страница 72: ...TH 50PF9UK 72 ...
Страница 73: ...14 Block and Schematic Diagram 14 1 Schematic Diagram Note TH 50PF9UK 73 ...
Страница 139: ...15 Parts Location 15 1 Exploded View 15 1 1 The main mechanical parts relation 139 TH 50PF9UK ...
Страница 140: ...15 1 2 Escutcheon part location enlarged views of lower left side 15 2 Fan part location enlarged views 140 TH 50PF9UK ...
Страница 141: ...15 3 Cable relation 141 TH 50PF9UK ...
Страница 142: ...15 4 Packing summary 142 TH 50PF9UK ...
Страница 143: ...143 TH 50PF9UK ...
Страница 144: ...144 TH 50PF9UK ...
Страница 145: ...145 TH 50PF9UK ...
Страница 147: ...17 Replacement Parts List 17 1 Replacement Parts List Notes 147 TH 50PF9UK ...