English
58
Serial ID function
Set to control external control with the PC connected to
SERIAL terminal according to the Display’s ID number
(Panel ID).
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
LAN control protocol
Select the LAN control protocol.
[Protocol 1]:
Control with the Panasonic Display sequence.
[Protocol 2]:
Control with the sequence that is compatible with
Panasonic Projector.
Note
●
For PJLink and WEB browser control, the operation is
possible regardless of the setting.
●
When performing the command control with TCP/IP,
select [Protocol 1].
●
When operating the “Early Warning Software” or
“Multi Monitoring & Control Software”, select [Protocol
2].
Information timing
Set up the informing manner for no signal or
temperature rising.
During RS-232C controls:
Warning or error message sent from the display
automatically.
During LAN controls:
Acquire the warning or error message from the
display.
1
Select the item with .
Select the set point with .
Information timing
No signal warning
No signal warning timing
No signal error timing
No signal error
On
5min
On
10min
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range: 01 ‒ 60, Interval: 1 minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
[No signal error timing]
Set up the detecting time for no signal error.
(Range: 01 ‒ 90, Interval: 1 minute)
●
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
functions:
[No signal power off], [HDMI1 power management],
[HDMI2 power management], [DVI-D power
management], [PC power management] (see page
45)
●
If there is no signal when [PC IN] is input, [PC
power management] is activated first and the
Display enters the standby mode.
Setting Example:
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
[PC power management]: [On] (60 seconds)
Note
●
The [No signal error timing] cannot be set shorter
than [No signal warning timing].
●
With the USB input, the unit determines video
signals are interrupted by judging the USB memory
is not connected to the USB terminal.
Power on screen delay
You can set the power-on delay time of the displays to
reduce the power load, when you press <Main Power
On / Off button> to turn on the multiple displays that are
set together.
Set each display’s setting individually.
[Off]:
The display will be turned on at the same time as
<Main Power On / Off button> is pressed.
[Auto]:
Sets the delay time automatically according to the
number set for [Display ID].
The delay time is determined by multiplying
[Display ID] × 0.3 seconds.
Example:
When [Display ID
] is 3 → 0.9 seconds
1 ‒ 30:
Set the power-on delay time (second).
After pressing <Main Power On / Off button>,
the display will be powered on with time delay
depending on this setting.