- 14 -
11- WHITE QUALITY CALIBRATION
PREPARATION:
1. Adjust the HELMHOLTZ device to local magnetic field. Ho-
rizontal: 0 ± 0.003 x 10
-4
T
2. Receive a white purity pattern.
3. Adjust CONTRAST and BRIGHT controls to maximum.
4. Previously adjust the CONVERGENCE.
5. Fully degauss the CRT by using an external degaussing
coil.
CALIBRATION:
1. Adjust the magnetic field in 0.4x10-4T (400 mG), and check
the white quality with the CRT turned to EAST and to WEST.
2. Receive a red pattern, adjust the COLOR control to
maximum and confirm the purity adjustment.
3. If purity error is found at the CRT corners, apply magnetic
tapes to correct it, fully degauss the CRT again and repeat
the steps 1 and 2. Don't use this magnetic tapes on the
internal side of the yoke.
4. Receive a white purity pattern, adjust the COLOR control
to minimum and confirm the purity adjustment.
12- CONVERGENCE CALIBRATION
1. Adjust the HELMHOLTZ device to local magnetic field.
2.
Receive a crosshatch pattern
.
3. Adjust IMAGE menu to DINÂMIC NORMAL and the DAC
BRIGHT control for the crosshatch pattern to be gray.
4.
Remove the DY wedges and slightly tilt the deflection
yoke to the vertically and horizontally to obtain the good
overall convergence.
5. If purity error is found, repeat “Color Purity” adjustment
CALIBRATION
Static convergence calibration
l) Assure that the magnets are positioned according to
illustration 1.
ll) Adjust the 4 poles magnets to align the R and B
CENTRAL DOTS and adjust the 6 poles magnets to
align both DOTS with G.
lll) After adjustment above, assure that the magnets are
sealed, through the application of white glue.
Note:
The electron beams are moved rotationally when the
static convergence magnets are rotated.
The reduction of rotational beams differ depending of
the two magnets angle. Therefore, it is necessary to
repeat the magnets calibrations sometimes, until
obtaining a good alignment.
13- CRT CUT OFF CALIBRATION
1. Supply a WINDOWS signal.
2. Position DACs with the data below:
BRT
—> 50H
S-BRT
—> 31H
RGB CONTRAST
—> 02H w/14” and 07H w/ 20” CRT
SUB-CONTRAST
—> 21H
R,G,B DRIVE
—> 31H
R,G CUT
—> 31H
CALIBRATION:
1. Press “5” (AKB OFF) and confirm that OSD becomes
blue.
2. Connect the oscilloscope in TPL5 and adjust BRT to
obtain 130V as in the Fig. 1 below.
3. Adjust the SCREEN to obtain a horizontal fine line in the
screen center.
Y = 1.0 +1.0 -0.5
4. Press “5” (AKB ON) and confirm that OSD becomes
white.
Fig. 1
ADJUSTMENTS
ITEM / PREPARATION
PROCEDURE
4 poles magnets (G-3)
6 poles magnets (R-G-B)
Содержание TC-14A04A
Страница 19: ...TC 14A04A TC 20A04A 19 MAIN PCB SCHEMATIC DIAGRAM SEE IC601 PINOUT TABLE BELOW IC601 PINOUT ...
Страница 20: ...TC 14A04A TC 20A04A 20 MAIN BOARD CIRCUIT LAYOUT ...
Страница 22: ...TC 14A04A TC 20A04A 22 Pin 42 Pin 55 IC601 Pin 18 Pin 19 Pin 38 Pin 40 ...
Страница 23: ... 23 TC 14A04A TC 20A04A Pin 64 IC601 Pin 56 Pin 57 Pin 58 Pin 63 ...
Страница 24: ...TC 14A04A TC 20A04A 24 Pin 1 IC804 Base Q501 Collector Collector Q551 Emiter Q601 Collector Q602 ...
Страница 25: ... 25 TC 14A04A TC 20A04A EXPLODED VIEW ...
Страница 36: ...Panasonic da Amazônia S A CS DIVISION TECHNICAL SUPPORT Rod Presidente Dutra Km 155 São José dos Campos SP ...