4.3 Heat reserving test
The above conditions are proper.
1. Put approx. 1 liter of water and the thermometer [ repairing tool (mercury thermometer ASN-150H) ]
in the pan, close the lid and turn on the boiling switch.
4.4 Hinge cover removal (Hinge cover)
1. Remove the dew collector.
2. Remove the hinge cover mounting screws.
3. As show in the figure, insert a narrow flat head screwdriver from just below and pry off the hinge cover.
2. When the beings boiling to generate steam turn off the boiling switch.
Within 69°C - 77°C .....................................Proper
If outside 69°C - 77°C, check triac mounting for irregularity, if it is proper, replace warming heater.
3. Add water or keep the lid opened until the reading of the thermometer falls to approx. 70°C.
4. When it becomes approx. 70°C, close the lid. After the warming heater is activated for 1 hour or more,
check the heat reserving temperature.
Top view of pan
Holes on the
tissue paper
Pan flange
Tissue paper
Mercury thermometer
Urethane foam blocks
Mercury thermometer
Inner Pan
SR-TMG18
PDF.js viewer
file:///C:/Users/SH49A5~1.DEH/AppData/Local/Temp/Rar$EXa0.684/v...
9 of 19
2016/05/02 3:47 PM
Содержание SR-TMG18
Страница 1: ...PDF js viewer file C Users SH49A5 1 DEH AppData Local Temp Rar EXa0 684 v 1 of 19 2016 05 02 3 47 PM ...
Страница 2: ...PDF js viewer file C Users SH49A5 1 DEH AppData Local Temp Rar EXa0 684 v 2 of 19 2016 05 02 3 47 PM ...
Страница 3: ...PDF js viewer file C Users SH49A5 1 DEH AppData Local Temp Rar EXa0 684 v 3 of 19 2016 05 02 3 47 PM ...
Страница 19: ...PDF js viewer file C Users SH49A5 1 DEH AppData Local Temp Rar EXa0 684 v 19 of 19 2016 05 02 3 47 PM ...