SR-GA421/SR-GA281/SR-GA721
4. TESTING PROCEDURE
3. Boiling control lever adjustment
Such a mechanical operation as center thermostat goes up and down is used to turn on
and off the micro-switch. Check and adjust this relationship as shown below.
When the boiling switch is turned on. When the boiling switch is turned off.
Checking
The auxiliary lever presses the push-
button (The “WARM” lamp comes on.)
The auxiliary lever does not press
the push-button (The “COOK” lamp
comes on.)
Adjusting
To gain the above relationship, adjust the auxiliary lever by bending it with
long nose pliers.