Notes:
S601:
Play switch (
)
S602:
Pause switch (
)
S603:
Stop switch (
)
S605:
Open/close switch (
)
S1001:
Tray open/close detect switch in OFF position
S2601:
Traverse switch in OFF position
- Indicated voltage values are the standard values for the unit
measured by the DC electronic circuit tester (high-impedance) with
the chassis taken as standard. Therefore, there may exist some
errors in the voltage values, depending on theinternal impedance
of the DC circuit tester.
No mark
: Stop
( )
: Play
- Important safety notice:
Components identified by mark have special characteristics
important for safety.
Furthermore, special parts which have purposes of fire-retardant
(resistors), high-quality sound (capacitors), low-noise (resistors),
etc. are used.
When replacing any of components, be sure to use only
manufacturer’s specified parts shown in the parts list.
37
Содержание SL-DT300EG
Страница 35: ...30 ...
Страница 36: ...31 ...
Страница 37: ...32 ...
Страница 38: ...33 ...
Страница 39: ...34 ...
Страница 40: ...35 ...
Страница 53: ...C3 ECJ1VB1H102K 50V 1000P 1 48 ...
Страница 65: ...21 Traverse Unit Parts Location 60 ...
Страница 66: ...22 Loading Unit Parts Location 61 ...
Страница 67: ...23 Schematic Diagram for printing with letter size F020300000YM KH 62 ...
Страница 98: ......