Mounting procedure

1. 

Fit the fixing claw (bottom side) from the top side or bottom side of the switch 
body along the root of the cable.

<When installing on the top side>

<When installing on the bottom side>

1

1

2. 

3XVKLQWKH¿[LQJFODZWRSVLGHWRVHFXUHLWRQWKHVZLWFKERG\

<When installing on the top side>

<When installing on the bottom side>

2

2

 

Ɣ

Removal procedure

The procedure for removing the maintenance actuator from the compact type is the 
same as that for removing the maintenance actuator from the visible type.

6

OUTPUT OPERATION AND INDICATOR OPERATION

When this product is installed on the switch body, the switch body outputs and the 
indicators operate as follows. This enables a distinction from an abnormal door open 
state.
Their operations for the collective maintenance type (

SG-PK-M1

DUHGLႇHUHQWIURP

those for the individual maintenance type (

SG-PK-M2

).

The operations of the switch body outputs and the indicators for each maintenance 
actuator are as described below.

WARNING

 

Ɣ

If the maintenance actuator is not used correctly, it will cause an accident.
When using the maintenance actuator, understand its operations well and 
use it correctly.

 

Ɣ

When using the collective maintenance type

Switch body (Standard)

Maintenance Actuator 

SG-PK-M1

Indicator

<Example: When connecting 3 units>

Standard unit

OSSD1 only turns ON

OSSD1

ON

OFF

OSSD2

Sub unit 1

Sub unit 2

Note: When using the collective maintenance type, the individual maintenance type (

SG-PK-M2

) cannot be used.

Normal actuator 

(Normal)

Normal actuator 

(Normal)

Maintenance 

actuator 

(Maintenance)

Type

Standard

Sub unit 1

Sub unit 2

OSSD1 OSSD2

Actuator

Detection 

state

Indicator Actuator

Detection 

state

Indicator Actuator

Detection 

state

Indicator

Collective 

mainte-

nance

Mainte-

nance

Detected

Yellow

Normal

Detected

Yellow

Normal

Detected

Yellow

ON

OFF

Detected

Yellow

Detected

Yellow

Not 

detected

Red

ON

OFF

Detected

Yellow

Not 

detected

Red

Detected

Yellow

ON

OFF

Not 

detected

Red

Detected

Blinking 

in green

Detected

Blinking 

in green

OFF

OFF

After 

12 hours 

(Note 1)

Detected

Blinking 

in yellow 

/ red

Detected

Blinking 

in yellow 

/ red

Detected

Blinking 

in yellow 

/ red

OFF

OFF

Notes: 1)  The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD1 

turns OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again, 
install it again.

 7KHLQGLFDWRURQWKHVZLWFKERG\EOLQNVLQ\HOORZUHGWRLQGLFDWHWZRGLႇHUHQWPRGHV)RUGHWDLOVUHIHUWRWKH

SG-P

 Series Instruction Manual.

 

Ɣ

When using the individual maintenance type

Switch body (Standard or sub)

Maintenance Actuator 

SG-PK-M2

Indicator

<Example: When connecting 3 units with the maintenance actuator installed on the sub unit 1>

Normal actuator 

(Normal)

Standard

OSSD2 only turns ON

OSSD1

OFF

ON

OSSD2

Sub unit 1

Sub unit 2

Normal actuator 

(Normal)

Maintenance 

actuator 

(Maintenance)

Type

Standard

Sub unit 1

Sub unit 2

OSSD1 OSSD2

Actuator

Detection 

state

Indicator Actuator

Detection 

state

Indicator Actuator

Detection 

state

Indicator

Individual 

mainte-

nance

Normal

Detected

Yellow

Mainte-

nance

Detected

Yellow

Normal

Detected

Yellow

OFF

ON

Not 

detected

Red

Detected

Blinking 

in yellow 

/ red

Detected

Blinking 

in yellow 

/ red

OFF

OFF

Detected

Blinking 

in green

Not 

detected

Red

Detected

Blinking 

in green

OFF

OFF

After 

12 hours 

(Note)

Detected

Blinking 

in yellow 

/ red

Detected

Blinking 

in yellow 

/ red

Detected

Blinking 

in yellow 

/ red

OFF

OFF

Note:  The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD2 turns 

OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again, install it 
again.

7

SPECIFICATIONS

Type

Collective maintenance type

Individual maintenance type

Model No.

SG-PK-M1

SG-PK-M2

Ambient temperature

0 to +40ºC (No condensation)

(storage: -25 to +65ºC)

Ambient humidity

35 to 85% RH

(storage: 35 to 85% RH) 

Vibration resistance

'XUDELOLW\WR+]

Double amplitude: 1 mm

2 hours each in X, Y, and Z directions

Shock resistance

Durability: 300 m/s

2

 (approx. 30 g)

3 times each in X, Y, and Z directions

Material

POM (polyacetal)

Weight

7 g

8

DIMENSIONS

Unit 

mm

23

39.5

8

3

2.5

102

1.5

10

.5

5

15.2

6.9

1.4

2.5

17

93

97.8

2

10.7

1.8

3.2

8

21

Panasonic Industrial Devices SUNX Co., Ltd. 

https://panasonic.net/id/pidsx/global

Please visit our website for inquiries and about our sales network.

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2021