Compact type
Ɣ
Mounting procedure
1.
Fit the fixing claw (bottom side) from the top side or bottom side of the switch
body along the root of the cable.
<When installing on the top side>
<When installing on the bottom side>
1
1
2.
3XVKLQWKH¿[LQJFODZWRSVLGHWRVHFXUHLWRQWKHVZLWFKERG\
<When installing on the top side>
<When installing on the bottom side>
2
2
Ɣ
Removal procedure
The procedure for removing the maintenance actuator from the compact type is the
same as that for removing the maintenance actuator from the visible type.
6
OUTPUT OPERATION AND INDICATOR OPERATION
When this product is installed on the switch body, the switch body outputs and the
indicators operate as follows. This enables a distinction from an abnormal door open
state.
Their operations for the collective maintenance type (
SG-PK-M1
DUHGLႇHUHQWIURP
those for the individual maintenance type (
SG-PK-M2
).
The operations of the switch body outputs and the indicators for each maintenance
actuator are as described below.
WARNING
Ɣ
If the maintenance actuator is not used correctly, it will cause an accident.
When using the maintenance actuator, understand its operations well and
use it correctly.
Ɣ
When using the collective maintenance type
Switch body (Standard)
Maintenance Actuator
SG-PK-M1
Indicator
<Example: When connecting 3 units>
Standard unit
OSSD1 only turns ON
OSSD1
ON
OFF
OSSD2
Sub unit 1
Sub unit 2
Note: When using the collective maintenance type, the individual maintenance type (
SG-PK-M2
) cannot be used.
Normal actuator
(Normal)
Normal actuator
(Normal)
Maintenance
actuator
(Maintenance)
Type
Standard
Sub unit 1
Sub unit 2
OSSD1 OSSD2
Actuator
Detection
state
Indicator Actuator
Detection
state
Indicator Actuator
Detection
state
Indicator
Collective
mainte-
nance
Mainte-
nance
Detected
Yellow
Normal
Detected
Yellow
Normal
Detected
Yellow
ON
OFF
Detected
Yellow
Detected
Yellow
Not
detected
Red
ON
OFF
Detected
Yellow
Not
detected
Red
Detected
Yellow
ON
OFF
Not
detected
Red
Detected
Blinking
in green
Detected
Blinking
in green
OFF
OFF
After
12 hours
(Note 1)
Detected
Blinking
in yellow
/ red
Detected
Blinking
in yellow
/ red
Detected
Blinking
in yellow
/ red
OFF
OFF
Notes: 1) The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD1
turns OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again,
install it again.
7KHLQGLFDWRURQWKHVZLWFKERG\EOLQNVLQ\HOORZUHGWRLQGLFDWHWZRGLႇHUHQWPRGHV)RUGHWDLOVUHIHUWRWKH
SG-P
Series Instruction Manual.
Ɣ
When using the individual maintenance type
Switch body (Standard or sub)
Maintenance Actuator
SG-PK-M2
Indicator
<Example: When connecting 3 units with the maintenance actuator installed on the sub unit 1>
Normal actuator
(Normal)
Standard
OSSD2 only turns ON
OSSD1
OFF
ON
OSSD2
Sub unit 1
Sub unit 2
Normal actuator
(Normal)
Maintenance
actuator
(Maintenance)
Type
Standard
Sub unit 1
Sub unit 2
OSSD1 OSSD2
Actuator
Detection
state
Indicator Actuator
Detection
state
Indicator Actuator
Detection
state
Indicator
Individual
mainte-
nance
Normal
Detected
Yellow
Mainte-
nance
Detected
Yellow
Normal
Detected
Yellow
OFF
ON
Not
detected
Red
Detected
Blinking
in yellow
/ red
Detected
Blinking
in yellow
/ red
OFF
OFF
Detected
Blinking
in green
Not
detected
Red
Detected
Blinking
in green
OFF
OFF
After
12 hours
(Note)
Detected
Blinking
in yellow
/ red
Detected
Blinking
in yellow
/ red
Detected
Blinking
in yellow
/ red
OFF
OFF
Note: The maintenance actuator is valid for the maximum of 12 hours consecutively. After 12 hours, the OSSD2 turns
OFF and the switch body indicator blinks (in yellow / red). When using the maintenance actuator again, install it
again.
7
SPECIFICATIONS
Type
Collective maintenance type
Individual maintenance type
Model No.
SG-PK-M1
SG-PK-M2
Ambient temperature
0 to +40ºC (No condensation)
(storage: -25 to +65ºC)
Ambient humidity
35 to 85% RH
(storage: 35 to 85% RH)
Vibration resistance
'XUDELOLW\WR+]
Double amplitude: 1 mm
2 hours each in X, Y, and Z directions
Shock resistance
Durability: 300 m/s
2
(approx. 30 g)
3 times each in X, Y, and Z directions
Material
POM (polyacetal)
Weight
7 g
8
DIMENSIONS
Unit
:
mm
23
39.5
8
3
2.5
102
1.5
10
㸴
.5
5
15.2
6.9
1.4
2.5
17
93
97.8
2
10.7
1.8
3.2
8
21
Panasonic Industrial Devices SUNX Co., Ltd.
https://panasonic.net/id/pidsx/global
Please visit our website for inquiries and about our sales network.
PRINTED IN JAPAN
© Panasonic Industrial Devices SUNX Co., Ltd. 2021