9
4.1.
Lock Search History Indication
1. Select [ 4 ] Lock search history indication.
Operation specifications
Indication contents
• Lock search history indication
Display the camera system error code for three histories saved in EEPROM.
• The error code contents which are displayed
Lock search history indication is finished by POWER OFF.
4.2.
Power ON Self Check Result Display
1. Select [ 5 ] Power ON self check result display.
Operation specifications
Indication contents
• Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
- CAM-PWR : Communication test between IC2304 to IC2006
- CAM-UNI : Communication test between IC3401 to IC2006
Display other than “OK” are abnormalities of each lines.
Power ON self check result display is finished by POWER OFF.
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal