Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
LOAD
Tray drive assembly
abnormal
Tray unit does not move
from “STOCK” to “PLAY”
position
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
PDRV
Cam gear/gear
assembly abnormal
Cam
gear
does
not
move from “HOME” to
“PLAY” drive position.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
UDU
UD base asssembly
abnormal
UD Base assembly does
not move upwards from
tray 5 to tray 2
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
UDD
UD base asssembly
abnormal
UD Base assembly does
not
move
downwards
from tray 1 to tray 5.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
UD1
UD base asssembly
abnormal
UD Base assembly does
not move to tray 1.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
F1NG
Fail - safe mode. (For
open/close tray
unit(s))
When
the
tray
open
operation is performed, it
fails
to
open.
It
will
automatically
close
all
trays after the time-out
by the microprocessor.
During this time when it
fails, the error code will
appear.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
F2NG
Fail - safe mode. (For
open/close tray
unit(s))
When
the
tray
close
operation is performed, it
fails
to
close.
It
will
automatically
open
all
trays after the time-out
by the microprocessor.
During this time when it
fails, the error code will
appear.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
SRVC_TRV
To unlock the
traverse unit for
service
1.
All
trays
set
to
“STOCK” position
2.
Mechanism
set
to
tray 5
3.
Cam
gear
set
to
“HOME” position
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit.
RSET
Cam gear jam/close
sensor faulty
During tray re-open, the
cam gear will rotate in
the opposite direction to
reset
the
cam
gear
position. When it fails,
the
error
code
will
appear.
For CD/DVD changer unit (CRS1D).
Press [SINGLE CHANGE] on main unit
for next error.
CRS1D Error Code display
1. The errors that occured in CRS1D Mechanism can be recalled and displayed, in the order of the occurence under self-
diagnostic (Refer to Section 10.3 for procedures to enter this mode.
•
Only the first 5 errors will be memorized (in backup memory). The subsequence error shall be ignored and not memorize.
39
SA-VK950GC / SA-VK950GS / SA-VK950GCS / SA-VK950GCT
38
manual de servicio SC-TM910DVD
Содержание SC-TM910DVD
Страница 16: ...7 4 DivX VOD Content 17 SA VK950GC SA VK950GS SA VK950GCS SA VK950GCT 16 manual de servicio SC TM910DVD ...
Страница 22: ...23 SA VK950GC SA VK950GS SA VK950GCS SA VK950GCT 22 manual de servicio SC TM910DVD ...
Страница 35: ...36 SA VK950GC SA VK950GS SA VK950GCS SA VK950GCT 35 manual de servicio SC TM910DVD ...
Страница 42: ...11 3 Main Parts Location 43 SA VK950GC SA VK950GS SA VK950GCS SA VK950GCT 42 manual de servicio SC TM910DVD ...
Страница 58: ...59 SA VK950GC SA VK950GS SA VK950GCS SA VK950GCT 58 manual de servicio SC TM910DVD ...