8.6.3. Power Supply & Digital Amplifier Error Code Table
Error
Code
F61
The abnormalities
In normal operation, when DCDET2 goes
Press [ STOP] on main
in an output or power
to "L" (Low) (Not during POWER OFF
unit for next error.
supply circuit of
condition), F61 appears on FLDisplay
POWER AMP
for 1 second and PCONT goes to
"L" (Low).This is due to speaker output
has DC voltage or fan is not working.
F76
Abnormality in the
In normal operation when DCDET1 is
Press [ STOP] on main
output voltage of
detected "L" (Low) for two consecutive
unit for next error.
stabilized power
times, F76 is displayed on FL for
supply
1 second and after that PCONT will be
turned to "L" (Low). This is due to any of
the DC voltages (+9V, +7V, -7V, +5V,
+5.3V etc.) C22 not available.
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
39
SA-PT660P / SA-PT660PC
Содержание SA-PT660P
Страница 7: ...Ref No Part No Part Name Description Remarks C5705 F1BAF1020020 1000pF M 7 SA PT660P SA PT660PC ...
Страница 12: ...12 SA PT660P SA PT660PC ...
Страница 25: ... Refer to Section 7 1 for the section on Remote Control Key Buttons Operations 25 SA PT660P SA PT660PC ...
Страница 45: ...45 SA PT660P SA PT660PC ...
Страница 47: ...9 2 Main Components and P C B Locations 47 SA PT660P SA PT660PC ...
Страница 71: ...Step 3 Release the catch and push the guide as arrows shown to close both grooves 71 SA PT660P SA PT660PC ...
Страница 92: ...SA PT660P SA PT660PC 92 ...
Страница 102: ...102 SA PT660P SA PT660PC ...
Страница 130: ...CN5501 Fig 3 Fan Connector 130 SA PT660P SA PT660PC ...
Страница 136: ...136 SA PT660P SA PT660PC ...
Страница 141: ...24 Exploded Views 24 1 Cabinet Parts Location SA PT660P SA PT660PC 141 ...
Страница 142: ...24 2 Packaging SA PT660P SA PT660PC 142 ...